BELOIT, WI —
OSHA Inspection: AMERICAN ALUMINUM EXTRUSION COMPANY, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of AMERICAN ALUMINUM EXTRUSION COMPANY, LLC in 1 ST. LAWRENCE AVENUE, BELOIT, WI 53511 (NAICS 331316). OSHA activity number 341666873.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AMERICAN ALUMINUM EXTRUSION COMPANY, LLC
- Site address
- 1 ST. LAWRENCE AVENUE
- City
- BELOIT
- State
- WI
- ZIP
- 53511
- Mailing
- 1 ST. LAWRENCE AVENUE, BELOIT, WI 53511
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331316
- Employees
- 53
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.132 D01 I
- Issued
- Aug 12, 2016
- Abate by
- Sep 2, 2016
- Penalty
- Initial $5,997 · Current $3,598 Reduced
General-duty citation text
29 CFR 1910.132(d)(1)(i): When the employer had assessed the workplace hazard(s) and determined that hazard(s) were present, the employer did not select and/or use the types of personal protective equipment that would protect the affected employee from the hazard identified. On or about August 2, 2016, and at times prior to and thereafter, the employer did not select and use the type of personal protective equipment that would protect employees tarping truckbeds from the JLG Toucan 20E boom mast lift from the hazard of falling to levels below.
Recent events (2)
- — I (S) $3598
- — Z (S) $5997
1910.147 C04 I
- Issued
- Aug 12, 2016
- Abate by
- Sep 30, 2016
- Penalty
- Initial $5,997 · Current $3,997 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about August 2, 2016, and at times prior to, the employer did not ensure that energy control procedures were utilized for the Cooling Table System Belts when employees were unjamming parts from the transfer system.
Recent events (2)
- — I (S) $3997
- — Z (S) $5997
More inspections at American Aluminum Extrusion Company, LLC
View American Aluminum Extrusion Company, LLC's full OSHA safety record →
More inspections in this industry (NAICS 331316)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341666873.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.