Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FIRE BRICK ENGINEERS COMPANY, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of FIRE BRICK ENGINEERS COMPANY, INC. in 2400 S 43RD ST, MILWAUKEE, WI 53219 (NAICS 333318). OSHA activity number 341681690.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fire Brick Engineers Company, INC. — free Get an email when a new federal OSHA severe-injury report for Fire Brick Engineers Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2400 S 43RD ST
City
MILWAUKEE
State
WI
ZIP
53219
Mailing
2400 S 43RD ST, MILWAUKEE, WI 53219
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333318
Employees
60
Ownership type
A

6 citations on file for this inspection.

1910.133 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 26, 2017
Abate by
Feb 22, 2017
Penalty
Initial $4,310 · Current $3,400 Reduced
29 CFR 1910.133(a)(1): Protective eye equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment:    (a) In the South Cutting Room, safety glasses with side shields, or other appropriate protective eye equipment was not required to be used by the worker operating the Large Saw. This exposed the worker to eye injury from breaking saw teeth.
Recent events (2)
  • — I (S) $3400
  • — Z (S) $4310

1910.147 C06 I

Other-than-serious 1 instance 2 exposed
Issued
Jan 26, 2017
Abate by
Feb 22, 2017
Penalty
Initial $3,231 · Current $0 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    (a) The employer did not conduct a periodic inspection of the energy control (lockout/tagout) procedure(s) for equipment, including but not limited to traveling head press, clicker presses, band saws and other equipment in the North and South Cutting Rooms.
Recent events (2)
  • — I (O) $0
  • — Z (S) $3231

1910.178 L01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 26, 2017
Penalty
Initial $4,310 · Current $3,400 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    (a)    The employer did not ensure that temporary employee(s) that operated forklift truck in the North Cutting Room had completed the forklift training and evaluation before operating a forklift.
Recent events (2)
  • — I (S) $3400
  • — Z (S) $4310

1910.212 A03 II

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 26, 2017
Abate by
Feb 22, 2017
Penalty
Initial $8,873 · Current $6,000 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):     (a) In the South Cutting Room, the operator of the Large Saw (Model # T1-10-40, Serial No. 4487) was exposed to cutting hazards and amputation injuries from inadvertent contact with exposed portions of the rotating radial arm saw blade.
Recent events (2)
  • — I (S) $6000
  • — Z (S) $8873

1910.242 B

Serious Gravity 1 2 instances 6 exposed
Issued
Jan 26, 2017
Abate by
Feb 22, 2017
Penalty
Initial $2,747 · Current $2,200 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:     (a) On or around 11/9/2016 in the North Cutting Room, compressed air for cleaning was used at approximately 70 p.s.i. (when dead-ended), potentially exposing workers to the hazard of air embolism.    (b) On or around 11/9/2016 in the South Cutting Room, compressed air for cleaning was used at approximately 70 p.s.i. (when dead-ended), potentially exposing workers to the hazard of air embolism.
Recent events (2)
  • — I (S) $2200
  • — Z (S) $2747

1910.1200 H03 II

Other-than-serious 1 instance 1 exposed
Issued
Jan 26, 2017
Abate by
Feb 22, 2017
Penalty
Initial $3,231 · Current $0 Reduced

Hazardous substances R251

29 CFR 1910.1200(h)(3)(ii): Employee training did not include the physical and health hazards of the chemicals in the work area:      (a)    The employee(s) performing power saw cutting to convert Cerafelt, a Refractory Ceramic Fiber (RCF) material, were not provided training which included that this substance is a suspected or potential human carcinogen.
Recent events (2)
  • — I (O) $0
  • — Z (S) $3231

View Fire Brick Engineers Company, INC.'s full OSHA safety record →