MILWAUKEE, WI —
OSHA Inspection: FIRE BRICK ENGINEERS COMPANY, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FIRE BRICK ENGINEERS COMPANY, INC. in 2400 S 43RD ST, MILWAUKEE, WI 53219 (NAICS 333318). OSHA activity number 347324493.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FIRE BRICK ENGINEERS COMPANY, INC.
- Site address
- 2400 S 43RD ST
- City
- MILWAUKEE
- State
- WI
- ZIP
- 53219
- Mailing
- 2400 S 43RD ST, MILWAUKEE, WI 53219
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333318
- Employees
- 40
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.176 B
- Issued
- Aug 2, 2024
- Abate by
- Aug 8, 2024
- Penalty
- Initial $5,485 · Current $5,485
General-duty citation text
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse, (a) On or about March 5, 2024, racking systems used for storage of parts and materials, created a crushing and struck-by hazard, in that the system was damaged in excess of the allowable limit of 0.5 inches of deflection within a 10 foot span, per ANSI MH16.1: 2021 'Specification for the Design, Testing and Utilization of Industrial Steel Storage Racks.' Specifically, but not limited to the following damaged rack areas were identified: The Green Line Rack: The horizontal beam was damaged with a deflection greater than 6 inches, creating a collapse and struck by hazard.
Recent events (1)
- — Z (S) $5485
1910.219 C03
- Issued
- Aug 2, 2024
- Abate by
- Sep 5, 2024
- Penalty
- Initial $5,485 · Current $5,485
General-duty citation text
29 CFR 1910.219(c)(3): Vertical or inclined shafting seven -7 feet or less from floor or working platform was not enclosed with stationary casing. (a) On or about March 5, 2024, employees were exposed to a caught in hazard due to lack of guarding around an auger shaft on the back left corner of the blue line water tank.
Recent events (1)
- — Z (S) $5485
1910.242 B
- Issued
- Aug 2, 2024
- Abate by
- Aug 21, 2024
- Penalty
- Initial $4,113 · Current $4,113
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i. (a) On or about March 5, 2024, an employee used a compressed air nozzle which was not reduced to 30 p.s.i. at the Green Line Tank to clean debris off product and the machines.
Recent events (1)
- — Z (S) $4113
1910.178 Q01
- Issued
- Aug 2, 2024
- Abate by
- Sep 5, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(q)(1): Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel. (a) On or about March 5, 2024, the employer did not ensure the Mitsubishi Caterpillar Forklift (Model: FGC25) was taken out of service that had mechanical deficiencies. The forklift did not have working lights, horn and brakes.
Recent events (1)
- — Z (O) $0
1910.212 B
- Issued
- Aug 2, 2024
- Abate by
- Sep 5, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving. (a) On or about March 5, 2024, A FATEK Wrapper NO: TP1650F-L and a Spiral Wrap Model #: ZS-70 were not secured to the working surface. Machines are not secure to the working surface while employees wrap materials which could expose employees to a struck by hazard.
Recent events (1)
- — Z (O) $0
1910.303 B01 II
- Issued
- Aug 2, 2024
- Abate by
- Aug 8, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(1)(ii): Electrical equipment was not free from recognized hazards, based on the mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided: (a) On or about March 5, 2024, the employer did not ensure the Hot Melt Press machine switch plate was effectively secured in place to prevent the cover plate from coming off. The cover plate was secured in place with tape.
Recent events (1)
- — Z (O) $0
More inspections at Fire Brick Engineers Company, INC.
View Fire Brick Engineers Company, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333318)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347324493.