MILWAUKEE, WI —
OSHA Inspection: FIRE BRICK ENGINEERS COMPANY, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FIRE BRICK ENGINEERS COMPANY, INC. in 2400 S 43RD ST, MILWAUKEE, WI 53219 (NAICS 333318). OSHA activity number 346850647.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FIRE BRICK ENGINEERS COMPANY, INC.
- Site address
- 2400 S 43RD ST
- City
- MILWAUKEE
- State
- WI
- ZIP
- 53219
- Mailing
- 2400 S 43RD ST, MILWAUKEE, WI 53219
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333318
- Employees
- 92
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.212 A03 II
- Issued
- Dec 1, 2023
- Abate by
- Dec 13, 2023
- Penalty
- Initial $10,938 · Current $8,750 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle: (a) On or about July 14, 2023, an employee working on the back side of the Atom Punch Press (Model No. S 3110/2 L CE, Serial No. 10036498), was able to access the point of operation that was not guarded, thereby exposing employees to a crushing and amputation hazard.
Recent events (2)
- — I (S) $8750
- — Z (S) $10938
1910.147 C06 I
- Issued
- Dec 1, 2023
- Abate by
- Dec 28, 2023
- Penalty
- Initial $5,313 · Current $2,656 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) On or about July 20, 2023, the employer did not assess the company hazardous energy control program annually to ensure machine specific energy control procedures were current, and that authorized employees were correctly implementing energy control procedures when performing maintenance and servicing work on equipment and associated processes.
Recent events (2)
- — I (S) $2656
- — Z (S) $5313
1910.305 A01 I
- Issued
- Dec 1, 2023
- Abate by
- Dec 7, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(a)(1)(i): Metal raceways, cable armor, and other metal enclosures for conductors were not metallically joined together into a continuous electric conductor: (a) On or about July 20, 2023, liquid tight flexible metal conduit (FMC) used to provide conductors to foot pedal of the Atom Punch Press (Model No. S 3110/2 L CE, Serial No. 10036498), was not joined together into a continuous electrical conductor. The FMC was broken away from the foot pedal connection point, exposing the electrical wires providing the electrical power to the foot pedal.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Fire Brick Engineers Company, INC.
View Fire Brick Engineers Company, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333318)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346850647.