DENVER, CO —
OSHA Inspection: INNOVATIONS MANUFACTURING INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of INNOVATIONS MANUFACTURING INC in 4555 GRAPE STREET, DENVER, CO 80216 (NAICS 332321). OSHA activity number 342002615.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- INNOVATIONS MANUFACTURING INC
- Site address
- 4555 GRAPE STREET
- City
- DENVER
- State
- CO
- ZIP
- 80216
- Mailing
- 4555 GRAPE STREET, DENVER, CO 80216
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332321
- Employees
- 12
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.36 B01
- Issued
- Mar 7, 2017
- Abate by
- May 15, 2017
- Penalty
- Initial $2,173 · Current $1,087 Reduced
General-duty citation text
29 CFR 1910.36(b)(1): At least two exits routes were not available to permit prompt evacuation of employees during an emergency: a) Innovations Manufacturing Inc. at 4555 Grape Street, Denver, CO: On and preceding December 29th 2016, the employer did not ensure at least two exits routes were available to permit prompt evacuation of employees during an emergency. The saw room was constructed of two metal framed walls covered in 1/2" thick plywood and two poured concrete walls with the space measuring approximately 36'x 61'. There was a single exit door. The employees used saws and punch presses to fabricate aluminum and vinyl products. The employer did not ensure that at least two egress routes were available for employees to exit the saw room. This condition exposed employees to a fire hazard.
Recent events (2)
- — I (S) $1087
- — Z (S) $2173
1910.37 B02
- Issued
- Mar 7, 2017
- Abate by
- Apr 10, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": a) Innovations Manufacturing Inc. at 4555 Grape Street, Denver, CO: On and preceding December 29th 2016, the employer did not ensure each exit was clearly visible and marked by a sign reading "Exit". The saw room was constructed of two metal framed walls covered in 1/2" thick plywood and two poured concrete walls with the space measuring approximately 36'x 61'. The single exit from the saw room was not marked by a sign reading "exit". The employees used saws and punch presses to fabricate aluminum and vinyl products. This condition exposed employees to a fire hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A03 II
- Issued
- Mar 7, 2017
- Penalty
- Initial $3,622 · Current $1,811 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point of operation of machinery were not guarded to prevent employees from having any part of their body in the danger zones during operating cycles: a) Innovations Manufacturing Inc. at 4555 Grape Street, Denver, CO: On and preceding December 29th 2016, the employer did not ensure point of operation of machinery was guarded to prevent employees from having any part of their body in the danger zones during operating cycles. One employee operated the Sampson Machine Co. model MN15012 Double Miter saw to cut vinyl. The employees used saws to fabricate vinyl products. This condition exposed employees to an amputation hazard.
Recent events (2)
- — I (S) $1811
- — Z (S) $3622
1910.217 C01 I
- Issued
- Mar 7, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.217(c)(1)(i): The employer did not provide and ensure the usage of point of operation guards or properly applied point of operation devices on every operation performed on mechanical power presses: a) Innovations Manufacturing Inc. at 4555 Grape Street, Denver, CO: On and preceding December 29th 2016, the employer did not ensure point of operation of machinery was guarded to prevent employees from having any part of their body in the danger zones during operating cycles. Point of operation guards were not installed on the 3 ton single action mechanical punch press. Employees used punch presses to fabricate aluminum products. This condition exposed employees to an amputation hazard; and b) Innovations Manufacturing Inc. at 4555 Grape Street, Denver, CO: On and preceding December 29th 2016, the employer did not ensure point of operation of machinery was guarded to prevent employees from having any part of their body in the danger zones during operating cycles. Point of operation guards were not installed on the 5 ton continuous action mechanical punch press. Employees used punch presses to fabricate aluminum products. This condition exposed employees to an amputation hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B02
- Issued
- Mar 7, 2017
- Abate by
- Apr 10, 2017
- Penalty
- Initial $2,173 · Current $1,087 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Innovations Manufacturing Inc. at 4555 Grape Street, Denver, CO: On and preceding December 29th 2016, the employer did not ensure listed or labeled electrical equipment was used or installed in accordance with instructions included in the listing or labeling. The saw room was equipped with three single miter saws, one chop saw, one double miter saw, shop lighting and other portable equipment. This equipment was powered by flexible cords that were in series with power strips and additional flexible extension cords. The flexible cords and power strips were daisy chained. The employees used saws and punch presses to fabricate aluminum and vinyl products. This condition exposed the employees to a fire hazard.
Recent events (2)
- — I (S) $1087
- — Z (S) $2173
1910.305 G01 IV A
- Issued
- Mar 7, 2017
- Abate by
- Apr 10, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Innovations Manufacturing Inc. at 4555 Grape Street, Denver, CO: On and preceding December 29th 2016, flexible cords and/or cables were used as a substitute for the fixed wiring of a structure. The double miter saw, chop saw, punch press and other equipment throughout the saw room was powered by flexible power cords and power strips due to an insufficient number of outlets. This condition exposed employees to fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV B
- Issued
- Mar 7, 2017
- Abate by
- Apr 28, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and/or cables were run through holes in walls, ceilings, or floors: a) Innovations Manufacturing Inc. at 4555 Grape Street, Denver, CO: On and preceding December 29th 2016, the employer did not ensure flexible power cords were not run through holes in walls, ceilings, or floors. The Atech Pegasus chop saw was plugged into a flexible extension cord which was run through a hole in the wall in the saw room and routed to an electrical panel outside of the saw room. This condition exposed the employees to electrical an hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.334 A02 I
- Issued
- Mar 7, 2017
- Abate by
- Apr 10, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): a) Innovations Manufacturing Inc. at 4555 Grape Street, Denver, CO: On or before December 29th 2016, the employer did not visually inspect portable cord and plug-connected equipment and flexible cord sets before use for external defects and for evidence of possible internal damage. The flexible power cord providing power to the 5 ton continuous operation punch press was damaged. The insulation was damaged and the conductor was exposed. This condition exposed the employees to an electrical hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Innovations Manufacturing INC
View Innovations Manufacturing INC's full OSHA safety record →
More inspections in this industry (NAICS 332321)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342002615.