WILLACOOCHEE, GA —
OSHA Inspection: WMT HOUSING, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of WMT HOUSING, LLC in 57 SUE MCCRANIE STREET SOUTH, WILLACOOCHEE, GA 31650 (NAICS 321991). OSHA activity number 342836715.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WMT HOUSING, LLC
- Site address
- 57 SUE MCCRANIE STREET SOUTH
- City
- WILLACOOCHEE
- State
- GA
- ZIP
- 31650
- Mailing
- 57 SUE MCCRANIE STREET SOUTH, WILLACOOCHEE, GA 31650
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321991
- Employees
- 165
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.37 A03
- Issued
- May 9, 2018
- Abate by
- Jun 12, 2018
- Penalty
- Initial $7,391 · Current $5,100 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: a) Main building, Tops, on or about December 14, 2017, the exit route outside the west exit door was blocked by a large plastic bucket, exposing employees to a hazard of receiving contusion and or fractures to their legs. b) Maintenance shop/tool room, on or about December 14, 2017, the exit door was pad locked and blocked, thus exposing employees to burns and smoke inhalation hazards.
Recent events (2)
- — I (S) $5100
- — Z (S) $7391
1910.37 B02
- Issued
- May 9, 2018
- Abate by
- Jun 12, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": a) Frame Shop, on or about December 14, 2017, the exit door leading from the shop area to the outside of the building was not marked "exit", exposing employees to burns and smoke inhalation hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.37 B06
- Issued
- May 9, 2018
- Abate by
- Jun 12, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color: a) Main Building, on or about December 14, 2017, employees were exposed to fire hazards while working in areas where the exit signs for the designated exit doors were not illuminated, exposing employees to burns and smoke inhalation hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.135 A01
- Issued
- May 9, 2018
- Abate by
- Jun 12, 2018
- Penalty
- Initial $7,391 · Current $5,100 Reduced
General-duty citation text
29 CFR 1910.135(a)(1): The employer did not ensure that each affected employee wear a protective helmet when working in areas where there is a potential for injury to the head from falling objects: a) Exterior, on or about December 14, 2017 and at times prior to, employees were not wearing head protection during roofing and framing work, resulting in a struck-by hazard.
Recent events (2)
- — I (S) $5100
- — Z (S) $7391
1910.252 B02 III
- Issued
- May 9, 2018
- Abate by
- Jun 12, 2018
- Penalty
- Initial $11,086 · Current $7,000 Reduced
General-duty citation text
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields: a) Frame Shop, on or about December 14, 2017,employees were performing stick and MIG welding operations inside the shop without welding screens in place to protect adjacent workers in the area from ultraviolet light burns.
Recent events (2)
- — I (S) $7000
- — Z (S) $11086
1910.305 D02
- Issued
- May 9, 2018
- Abate by
- Jun 12, 2018
- Penalty
- Initial $5,543 · Current $3,800 Reduced
General-duty citation text
29 CFR 1910.305(d)(2): Panelboards, other than the dead front externally-operable type and accessible only to qualified persons, were not mounted in cabinets, cutout boxes, or enclosures designed for the purpose and/or were not dead front: a) Frame Shop, on or about December 14, 2017, and at times prior to, the employer exposed employees to electrical shock hazards, in that the breaker panel had unused openings in the face plate. b) Frame Shop, on or about December 14, 2017, and at times prior to, the employer exposed employees to electrical shock hazards, in that a 240 volts, three phase electrical breaker panel was not dead front.
Recent events (2)
- — I (S) $3800
- — Z (S) $5543
1910.305 G01 IV A
- Issued
- May 9, 2018
- Abate by
- Jun 12, 2018
- Penalty
- Initial $5,543 · Current $3,800 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Floor Department, on or about December 14, 2017, flexible cord was being used on a permanent basis to provide power to the Lasalle Brisrtol Manufacturer Duct Work Machine, resulting in an electrical hazard. b) Floor Department, on or about December 14, 2017, flexible cord was being used on a permanent basis to provide power to the DeWalt Chop Saw, resulting in an electrical hazard.
Recent events (2)
- — I (S) $3800
- — Z (S) $5543
1904.39 A02
- Issued
- May 9, 2018
- Penalty
- Initial $9,239 · Current $6,400 Reduced
General-duty citation text
29 CFR 1904.39(a)(2): The employer failed to report the in-patient hospitalization of one or more employees or an employee's amputation or an employee's loss of an eye, as a result of a work-related incident, within (24) twenty-four hours: a) At the plant, on or about December 14, 2017, the employer had at least three separate cases resulting in hospitalization that were not reported to OSHA within 24 hours.
Recent events (2)
- — I (O) $6400
- — Z (O) $9239
1910.303 F02
- Issued
- May 9, 2018
- Abate by
- Jun 12, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(f)(2): Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, unless located and arranged so the purpose is evident: a) Frame Shop, on or about December 14, 2017, the electrical panel boxes for the overhead crane, welders, and lights were not labeled, exposing employees to electrical and burn hazards. b) Final Finish Shop, on or about December 14, 2017, the electrical panel box for the lights were not labeled, exposing employees to electrical hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 E01
- Issued
- May 9, 2018
- Abate by
- Jun 12, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) At the facility, on or about December 14, 2017, and at time prior to, the employer did not develop a written hazard communication program for chemicals used such as propane, diesel fuel, mineral spirit, foam seal and ceiling mud by employees at the facility, exposing employees to skin irritation and allergic dermatitis.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 H01
- Issued
- May 9, 2018
- Abate by
- Jun 12, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) At the facility, on or about December 14, 2017, and at time prior to, the employer did not provide information and training to employees who work with hazardous chemical such as, propane, diesel fuel, mineral spirit, foam seal and ceiling mud at the facility, exposing employees to skin irritation and allergic dermatitis.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at WMT Housing, LLC
View WMT Housing, LLC's full OSHA safety record →
More inspections in this industry (NAICS 321991)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342836715.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.