Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TOLEDO REFINING COMPANY LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of TOLEDO REFINING COMPANY LLC in 1819 WOODVILLE RD., OREGON, OH 43616 (NAICS 324110). OSHA activity number 343078952.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Toledo Refining Company LLC — free Get an email when a new federal OSHA severe-injury report for Toledo Refining Company LLC is published. One employer, no account, unsubscribe in one click.
Site address
1819 WOODVILLE RD.
City
OREGON
State
OH
ZIP
43616
Mailing
1819 WOODVILLE RD., OREGON, OH 43616
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
324110
Employees
500
Ownership type
A

2 citations on file for this inspection.

1910.119 J06 III

Deleted Serious Gravity 10 1 instance 10 exposed
Issued
Sep 26, 2018
Abate by
Oct 22, 2018
Penalty
Initial $12,934 · Current $0 Reduced
29 CFR 1910.119(j)(6)(iii): The employer did not assure that maintenance materials, spare parts and equipment are suitable for the process application for which they were used:  a)  Toledo Refining Company, LLC - Oregon, Ohio:  On or about April 11, 2018, the employer did not ensure that replacement components for the burner assembly in the H-9502 were suitable for the original design of the burner.  The rebuild of the heater/burner following the March 1, 2018 incident included components from a different revision of the design of the equipment.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (3)
  • — F (S) $0
  • — C (S) $12934
  • — Z (S) $12934

1910.119 D03 II

Other-than-serious 1 instance 10 exposed
Issued
Sep 26, 2018
Abate by
Feb 1, 2019
Penalty
Initial $12,934 · Current $0 Reduced
29 CFR 1910.119(d)(3)(ii):  The employer did not document that equipment complies with recognized and generally accepted good engineering practices:    a) Toledo Refining Company, LLC  Oregon, Ohio:  On or about April 11, 2018, the employer did not document that it had in place quality assurance steps, consistent with API Recommended Practice 535, Burners for Fire Heaters in General Refinery Services, sufficient to ensure that certain third-party supplied replacement components for a heater burner assembly were consistent with the then-current burner design.
Recent events (3)
  • — F (O) $0
  • — C (S) $12934
  • — Z (S) $12934

View Toledo Refining Company LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343078952.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.