Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THE MEDALCRAFT MINT, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of THE MEDALCRAFT MINT, INC. in 2660 W. MASON ST., GREEN BAY, WI 54303 (NAICS 332116). OSHA activity number 344553391.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Medalcraft Mint, INC. — free Get an email when a new federal OSHA severe-injury report for The Medalcraft Mint, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2660 W. MASON ST.
City
GREEN BAY
State
WI
ZIP
54303
Mailing
2660 W. MASON ST., GREEN BAY, WI 54303
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332116
Employees
104
Ownership type
A

8 citations on file for this inspection.

1910.147 C06 I

Serious Gravity 5 1 instance 4 exposed
Issued
May 8, 2020
Penalty
Initial $8,675 · Current $4,338 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    a)    On or about 1/14/2020, Employer had not conducted the annual periodic inspection for 2019 of their energy control procedures. The review should have included each authorized employee.
Recent events (2)
  • — I (S) $4337.5
  • — Z (S) $8675

1910.147 C07 I A

Serious Gravity 5 1 instance 4 exposed
Issued
May 8, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.  a)    On or about 1/14/2020, Employer had not trained all of their press operators in energy control procedures to the authorized employee level.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.217 B07 III

Serious Gravity 10 12 instances 7 exposed
Issued
May 8, 2020
Penalty
Initial $12,145 · Current $6,073 Reduced
29 CFR 1910.217(b)(7)(iii): Mechanical power presses using part revolution clutches were not provided with a means of selecting off, inch, single stroke, and continuous (when the continuous function was furnished) with the clutch/brake control to select type of operation of the press. Fixing of selection shall be by means capable of supervision by the employer.    a)    On or about 1/22/2020, Collar press P-7 was not equipped with a key switch for the run/inch function which would permit supervision by the employer. For the presses with keys the employer was not requiring the removal of keys that control the selector switches for the press modes during press operation which would permit operation in an unguarded mode.
Recent events (2)
  • — I (S) $6072.5
  • — Z (S) $12145

1910.217 B07 X

Serious Gravity 5 2 instances 2 exposed
Issued
May 8, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.217(b)(7)(x): Foot operated tripping control(s) used mechanical power press(es) with part revolution clutches were not protected to prevent operation from falling or moving objects, or from unintended operation by accidental stepping onto the foot control.   a)    On or about 1/22/2020, Foot control was not guarded on P-7 Collar press allowing for accidental operation of the press exposing the operator to a life changing hand injury.  b)    On or about 1/22/2020, Foot control was not guarded on PR-013 Denison Multi Press allowing for accidental operation of the press with potential operator injury exposure.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.217 C02 I A

Serious Gravity 5 1 instance 2 exposed
Issued
May 8, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.217(c)(2)(i)(a): Point of operation guard(s) on mechanical power press(es) did not prevent entry of hands or fingers into the point of operation by reaching through, over, under or around the guard(s).   a)    On or about 1/22/2020, Point of operation guards on P-7 Collar press did not prevent entry of hands or fingers into the point of operation creating a risk of serious injury for the operator.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.217 D09 IV

Serious Gravity 5 1 instance 2 exposed
Issued
May 8, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.217(d)(9)(iv): Safety blocks were not used when mechanical power press die(s) were being adjusted or repaired in the press:   a)    On or about 1/22/2020, P-7 Collar press did not have a safety block available for use during setup and their use was not being enforced.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.217 E01 I C

Serious Gravity 5 12 instances 7 exposed
Issued
May 8, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.217(e)(1)(i)(C): Records were not maintained for each inspection, maintenance and/ or repair task performed which included the date of inspection, maintenance or repair work, signature of the person who performed the inspection, maintenance or repair work and the serial number or other identifier of the power press inspected, maintained or repaired.   a)    On or about 1/22/2020, The company had 12 mechanical power presses which were being inspected by the Maintenance Supervisor daily but did not maintain a written certification record for those inspections, maintenance or repairs performed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 F01

Other-than-serious 3 instances 1 exposed
Issued
May 8, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(1): Each disconnecting means required by Subpart S of Part 1910 for motors and appliances was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  a)    On or about 1/22/2020, Three disconnects mounted on the East wall of the back room were not labeled at the time of the inspection.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View The Medalcraft Mint, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344553391.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.