Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: API TECHNOLOGIES CORP.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of API TECHNOLOGIES CORP. in 8061 AVONIA ROAD, FAIRVIEW, PA 16415 (NAICS 335999). OSHA activity number 344694674.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch API Technologies Corp. — free Get an email when a new federal OSHA severe-injury report for API Technologies Corp. is published. One employer, no account, unsubscribe in one click.
Site address
8061 AVONIA ROAD
City
FAIRVIEW
State
PA
ZIP
16415
Mailing
8061 AVONIA ROAD, FAIRVIEW, PA 16415
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335999
Employees
185
Ownership type
A

7 citations on file for this inspection.

1910.134 C02 II

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 3, 2020
Abate by
May 20, 2020
Penalty
Initial $4,916 · Current $2,250 Reduced
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user:     a)    API Technologies Corporation, Production areas, on or about March 13th, 2020 and times prior thereto:  Some employees voluntarily used air purifying half mask respirators (Honeywell brand 5500-30 serious with Honeywell organic vapor cartridges) during various work tasks including, but not limited to, cleaning operations.  The company did not establish portions of a respiratory protection program that covered medical evaluations and respirator maintenance and care.       ABATEMENT CERTIFICATION REQUIRED:   Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $2250
  • — Z (S) $4916

1910.134 C02 I

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 3, 2020
Abate by
May 20, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:    a)  API Technologies Corporation, Production areas, on or about March 13th, 2020 and times prior thereto:  Some employees voluntarily used air purifying half mask respirators (Honeywell brand 5500-30 serious with Honeywell organic vapor cartridges) during various work tasks including, but not limited to, cleaning operations.  Employees that voluntarily used half mask respirators were not provided with the information in Appendix D to this section.       ABATEMENT CERTIFICATION REQUIRED:  Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 E01

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 3, 2020
Abate by
May 20, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:    a)   API Technologies Corporation, Production areas, on or about March 13th, 2020 and times prior thereto:  Some employees voluntarily used air purifying half mask respirators (Honeywell brand 5500-30 serious with Honeywell organic vapor cartridges) during various work tasks including, but not limited to, cleaning operations.  Employees were not provided with medical evaluations prior to use of the air purifying half mask respirators.   ABATEMENT CERTIFICATION REQUIRED:   Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 D01 III

Deleted Serious Gravity 1 1 instance 15 exposed
Issued
Apr 3, 2020
Penalty
Initial $4,178 · Current $0 Reduced
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form:  a)  API Technologies Corporation, Compressor/Generator room and Production areas, on or about March 13th, 2020 and times prior thereto:  Employees were potentially exposed to carbon monoxide during backup generator operations onsite.  Employees experienced health related symptoms due the exposure to carbon monoxide onsite.  The employer did not evaluate the workplace to determine employees exposure levels to carbon monoxide during backup generator operations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4178

1910.1200 H03 II

Deleted Serious Gravity 1 1 instance 15 exposed
Issued
Apr 3, 2020
Abate by
May 20, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(3)(ii): Employee training did not include the physical and health hazards of the chemicals in the work area:    a)  API Technologies Corporation, Compressor/Generator room and Production areas, on or about March 13th, 2020 and times prior thereto:  Employees were potentially exposed to carbon monoxide during backup generator operations onsite.  Employees experienced health related symptoms due the exposure to carbon monoxide onsite.  Training on the health hazards of carbon monoxide had not been provided to employees onsite.   ABATEMENT CERTIFICATION REQUIRED:  Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G01 II

Serious Gravity 1 1 instance 15 exposed
Issued
Apr 3, 2020
Penalty
Initial $4,178 · Current $2,250 Reduced
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:     a)     API Technologies Corporation, Generator/Compressor room, on or about March 13th, 2020 and times prior thereto:  Items including, but not limited to, a 55 gallon drum of diesel fuel were stored directly in front of a 480 volt electrical panel box.  The employer did not ensure the area in front of the electrical panel box was kept clear for access.
Recent events (2)
  • — I (S) $2250
  • — Z (S) $4178

1910.305 B02 I

Serious Gravity 1 1 instance 15 exposed
Issued
Apr 3, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:    a.)  API Technologies Corporation, Generator/Compressor room, on or about March 13th, 2020 and times prior thereto:  A metal junction box that had wire capped splices was not equipped with a cover plate.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View API Technologies Corp.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344694674.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.