GREEN BAY, WI —
OSHA Inspection: LEGACY FLEXO
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of LEGACY FLEXO in 1327 GLORY RD, GREEN BAY, WI 54304 (NAICS 323111). OSHA activity number 345214084.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LEGACY FLEXO
- Site address
- 1327 GLORY RD
- City
- GREEN BAY
- State
- WI
- ZIP
- 54304
- Mailing
- 1327 GLORY RD, GREEN BAY, WI 54304
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323111
- Employees
- 120
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.106 E02 II B 2
- Issued
- May 21, 2021
- Abate by
- Jul 13, 2021
- Penalty
- Initial $7,461 · Current $5,223 Reduced
General-duty citation text
29 CFR 1910.106(e)(2)(ii)(b)(2): The quantity of liquid that may be located outside of an inside storage room or storage cabinet in a building or in any one fire area of a building shall not exceed: 120 gallons of Category 2, 3, or 4 flammable liquids in containers. In the Press Room near the east wall , the employer did not ensure that Category 2 and 3 flammable liquids stored outside of an inside storage room or storage cabinet in the building or in any one fire area of the building did not exceed 120 gallons, exposing employees to fire and burn hazards in the following instances: a) One steel 55-gallon drum containing approximately 27 gallons of Acetone (Category 2 flammable liquid); b) Two steel 55-gallon drums containing approximately 110 gallons of N-Propyl Acetate (Category 2 flammable liquid); c) One steel 55-gallon drum containing approximately 55 gallons of Barsol PNP (Category 3 flammable liquid); d) Two steel 55-gallon drums containing approximately 110 gallons of N-Propyl Alcohol (Category 3 flammable liquid).
Recent events (2)
- — I (S) $5222.7
- — Z (S) $7461
1910.106 E06 I
- Issued
- May 21, 2021
- Abate by
- Jun 21, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(e)(6)(i): "General." Adequate precautions shall be taken to prevent the ignition of flammable vapors. Sources of ignition include but are not limited to open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat. The employer did not ensure that containers used to transfer flammable liquids were electrically interconnected to prevent the accumulation of static electricity, exposing employees to fire and burn hazards in the following instances: a) At the Fischer & Krenke Press, employees transferring IPA 99 (Category 2 flammable liquid) from IBCs into metal containers without the containers being grounded and bonded; b) At the Comexi FX2108, employees transferring Barsol A-2154 (Category 2 flammable liquids) from IBCs into metal containers without the containers being bonded; c) At the Comexi FX2108 Press, employees transferring IPA 99 (Category 2 flammable liquid) from metal containers into metal containers without the containers being bonded; d) At the Fusion C Press, employees transferring IPA 99 (Category 2 flammable liquid) from a metal container to another container without the containers being grounded and bonded; e) At the Fusion Max Press, employees transferring IPA 99 and Barsol A-2154 (Category 2 flammable liquids) from metal containers into metal containers without the containers being bonded.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.106 E09 IV
- Issued
- May 21, 2021
- Abate by
- Jun 21, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(e)(9)(iv):"Clear zone." Ground area around buildings and unit operating areas shall be kept free of weeds, trash, or other unnecessary combustible materials. At the Provision Press, a stainless steel IBC container holding Barsol A-2154 (Category 2 flammable liquid) was stored unnecessarily on top of five wood pallets, a combustible material, exposing employees to fire and burn hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.132 A
- Issued
- May 21, 2021
- Abate by
- Jun 21, 2021
- Penalty
- Initial $7,461 · Current $5,223 Reduced
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: At the Provision Press, Fusion C Press, and Fusion Max Press, the employer did not ensure that employees using the ammonium hydroxide solution at the presses were wearing the correct PPE (face shield and rubber gloves) as required by the hazard assessment, exposing employees to health hazards.
Recent events (2)
- — I (S) $5222.7
- — Z (S) $7461
1910.212 A01
- Issued
- May 21, 2021
- Abate by
- Jun 21, 2021
- Penalty
- Initial $4,476 · Current $3,133 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: The employer did not ensure that the shafts for pneumatic mixers were guarded, exposing employees to entanglement hazards in the following instances: a) At the Comexi F2 Press, one clamp mounted pneumatic mixer affixed to one 55-gallon drum was observed in use; b) At the Comexi FX2108 Press, two clamp mounted pneumatic mixers affixed to two 55-gallon drums were observed in use.
Recent events (2)
- — I (S) $3133.2
- — Z (S) $4476
1910.1200 E01
- Issued
- May 21, 2021
- Abate by
- Jun 21, 2021
- Penalty
- Initial $5,969 · Current $4,178 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1):Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met. The employer did not ensure that their Hazard Communication Program included all of the elements as required in the Hazard Communication Standard, exposing employees to health and fire hazards. Elements that were not included in the employer's Hazard Communication Program included: a) Explanation of alternative labeling methods for chemicals used in the facility, making it difficult to identify the chemical and the hazards present; b) Informing employees of the hazards in non-routine tasks; c) Methods to provide the other employers on-site access to SDSs, precautionary measures, and labeling system used.
Recent events (2)
- — I (S) $4178.3
- — Z (S) $5969
1910.1200 F06
- Issued
- May 21, 2021
- Abate by
- Jun 21, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(6):Workplace labeling. Except as provided in paragraphs (f)(7) and (f)(8) of this section, the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical: In the Press Room, the employer did not ensure that containers of hazardous chemicals were labeled, tagged or marked, or labeling present was unobscured, exposing employees to chemicals and fire hazards in the following instances: a) At the Provision Press, four plastic containers containing degreaser, IPA 99, oil, and glycol; b) At the Provision Press, one metal container containing white ink; c) At the Comexi FX2108 Press, one metal container containing IPA 99; d) At the Fusion C+ Press, three safety cans containing IPA 99; e) At the Fusion C Press, one metal container containing IPA 99; f) At the Fusion C Press, two safety cans containing approximately 10 gallons of Barsol A-2154; g) Along the east wall, three metal containers containing approximately 15 gallons of RotoFlex G Quinacridone; h) Along the east wall, two metal containers containing approximately 10 gallons of Rotoflex G Cyan Green.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.106 D02 I
- Issued
- May 21, 2021
- Abate by
- Jun 21, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(d)(2)(i): Only approved containers and portable tanks shall be used. Metal containers and portable tanks meeting the requirements of and containing products authorized by chapter I, title 49 of the Code of Federal Regulations (regulations issued by the Hazardous Materials Regulations Board, Department of Transportation), shall be deemed to be acceptable. At the Provision Press, the employer did not ensure that a container containing IPA 99 (Category 2 flammable liquid) was stored in an approved container, exposing an employee to fire and burn hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.106 D02 III
- Issued
- May 21, 2021
- Abate by
- Jun 21, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(d)(2)(iii):Size. Flammable liquid containers shall be in accordance with Table H-12. The maximum allowable size for Category 2 flammable liquids in glass or approved plastic containers was 1 quart. At the Provision Press, the employer did not ensure that a container containing IPA 99 (Category 2 flammable liquid) was stored in a container with a maximum allowable size of one quart, exposing an employee to fire and burn hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Legacy Flexo
View Legacy Flexo's full OSHA safety record →
More inspections in this industry (NAICS 323111)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345214084.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.