Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TENSION ENVELOPE CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TENSION ENVELOPE CORPORATION in 5900 TENSION DR., FORT WORTH, TX 76112 (NAICS 322230). OSHA activity number 345329783.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tension Envelope Corporation — free Get an email when a new federal OSHA severe-injury report for Tension Envelope Corporation is published. One employer, no account, unsubscribe in one click.
Site address
5900 TENSION DR.
City
FORT WORTH
State
TX
ZIP
76112
Mailing
5900 TENSION DR., FORT WORTH, TX 76112
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322230
Employees
70
Ownership type
A

5 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 5 1 instance 62 exposed
Issued
Jul 26, 2021
Abate by
Aug 23, 2021
Penalty
Initial $7,724 · Current $4,634 Reduced
29 CFR  1910.147(c)(4)(ii):Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance:  On or about  May 13, 2021  and at times prior thereto, the employer did not ensure the energy control procedures included the scope, purpose, authorization and rules and methods to enforce the lock-out procedures exposing employees to caught-in, struck-by and amputations hazards.
Recent events (2)
  • — I (S) $4634.4
  • — Z (S) $7724

1910.147 C06 I C

Other-than-serious Gravity 5 1 instance 62 exposed
Issued
Jul 26, 2021
Abate by
Aug 23, 2021
Penalty
Initial $7,724 · Current $4,634 Reduced
29 CFR  1910.147(c)(6)(i)(C): Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected:   On or about May 13, 2021 and at times prior thereto, the employer did not perform periodic inspections between each authorized employees and the inspector to determine the energy control procedure was working effectively, exposing employees to struck-by, caught-in and amputation hazards.
Recent events (2)
  • — I (O) $4634.4
  • — Z (S) $7724

1910.147 C06 II

Other-than-serious Gravity 5 1 instance 62 exposed
Issued
Jul 26, 2021
Abate by
Aug 23, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(6)(ii):The periodic inspection certification of energy control procedures did not contain the required documentation on identification of the machine or equipment, inspection date, employees included, and the person performing the inspections:  On or about May 13, 2021, and at times prior thereto, the employer did not ensure that the energy control procedures utilized at the facility were certified and documented as required annually.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.147 C07

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 26, 2021
Abate by
Aug 5, 2021
Penalty
Initial $11,586 · Current $6,952 Reduced
29 CFR 1910.147(c)(7): At this establishment, the employer had not provided training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices was acquired by the employees.  In the production area, the employer did not provide adequate training to ensure obtained the knowledge, skills and familiarization with the lockout/tagout application and procedures when operating and servicing equipment, such as but not limited to the 02-40-527 WEB R-7, envelope machine, serial number 9731, exposing employees to the hazard of being caught in or struck by the equipment.
Recent events (2)
  • — I (S) $6951.6
  • — Z (S) $11586

1910.147 C06 I

Repeat Gravity 5 1 instance 1 exposed
Issued
Jul 26, 2021
Abate by
Aug 23, 2021
Penalty
Initial $15,448 · Current $9,269 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  In the production area, the employer did not perform periodic annual inspections to ensure the Lockout/Tagout Program is working effectively, such as but not limited to 02-40-527 WEB envelope folding machine. Reviews were not conducted to determine if listed steps were still adequate, if any changes had occurred, or if employees had acquired the knowledge needed to effectively isolate energy sources.  Tension Envelope Corporation was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.147(c)(6)(i), which was contained in OSHA inspection number 1248138, Citation Number 1, Item number 1, and was affirmed as a final order on October 17, 2017, with respect to a workplace located at 819 East 19th Street , Kansas City, Missouri 64108.
Recent events (2)
  • — I (R) $9268.8
  • — Z (R) $15448

View Tension Envelope Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345329783.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.