PALM SPRINGS, CA —
OSHA Inspection: INDIAN CANYONS GOLF RESORT
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of INDIAN CANYONS GOLF RESORT in NORTH COURSE 1100 E MURRAY CANYON DRIVE, PALM SPRINGS, CA 92264 (NAICS 713910). OSHA activity number 345487607.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- INDIAN CANYONS GOLF RESORT
- Site address
- NORTH COURSE 1100 E MURRAY CANYON DRIVE
- City
- PALM SPRINGS
- State
- CA
- ZIP
- 92264
- Mailing
- NORTH COURSE 1100 E MURRAY CANYON DRIVE, PALM SPRINGS, CA 92264
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 713910
- Employees
- 20
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.157 C01
- Issued
- Sep 20, 2021
- Penalty
- Initial $1,989 · Current $1,392 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): A portable fire extinguisher was blocked and not available for immediate use by employees. Northeast Mechanical Tool Shed: Where the employer provided portable fire extinguishers, the extinguisher on the South side of the shed entryway was blocked from access. This condition exposed the employees to hazards associated with fire such as burns and smoke inhalation.
Recent events (2)
- — I (S) $1392.3
- — Z (S) $1989
1910.178 A04
- Issued
- Sep 20, 2021
- Abate by
- Feb 4, 2022
- Penalty
- Initial $2,653 · Current $0 Reduced
General-duty citation text
29 CFR 1910.178(a)(4): Modifications and additions which could possibly affect capacity and safe operation were performed by the customer without manufacturers prior written approval: North Course Exterior Shop Area: Employee(s) operated the Kubota Loader to move green waste trash to a storage stall and used for seeding tasks. The Kubota Loader was electrically modified by installing an activation switch for the ability to attach a seeing element on the rear of the loader without manufactures prior written approval. This condition exposes employee(s) to operating clearances, capacity, stability, obstruction and/or struck by, caught in-between hazard(s).
Recent events (2)
- — I (S) $0
- — Z (S) $2653
1910.178 Q01
- Issued
- Sep 20, 2021
- Abate by
- Feb 4, 2022
- Penalty
- Initial $0 · Current $1,592
General-duty citation text
29 CFR 1910.178(q)(1): Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel: North Course Exterior Shop Area: The LA 1001 Kubota Front loader was found with inoperable break lights and no back up alarm and was not removed from service. Employees were operating the Kubota to transport green waste trash into storage stall. This condition exposed employees to no advanced warning such as backing up, stopping and/or struck by hazard(s).
Recent events (2)
- — I (S) $1591.8
- — Z (S) $0
1910.178 Q07
- Issued
- Sep 20, 2021
- Abate by
- Oct 15, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(q)(7): Industrial trucks were not examined daily before being placed in service. North Course Exterior Shop Area: The employer did not examine the LA 1001 Kubota Front loader for defects that would impair the safe operation daily. The loader was found with inoperable break lights and no back up alarm. Employees were operating the Kubota to transport green waste trash into storage stall. This condition exposed employees to no advanced warning such as backing up, stopping and/or struck by hazard(s).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B02
- Issued
- Sep 20, 2021
- Penalty
- Initial $2,653 · Current $1,857 Reduced
General-duty citation text
29 CFR 1910.303(b)(2):Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: In the follow locations, appliances were plugged into power taps and were not used according to listing and labeling instructions. a) Maintenance Shop, West Superintendents office - The refrigerator was plugged directly into a relocatable power tap. b) Administration Building Breakroom- The microwave, toaster and coffee maker were plugged directly into a relocatable power tap. Employees were exposed to electrical shock and/or fire hazards.
Recent events (2)
- — I (S) $1857.1
- — Z (S) $2653
1910.303 G01 II
- Issued
- Sep 20, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(ii):The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: Maintenance Shop West Superintendents Office: The employer permitted materials to be directly stored in front of the electrical panel. This condition interferes with access and immediate shutdown of a circuit in the panel, particularly in the event of an emergency. Employees were exposed to electrical and/or fire hazard(s).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.334 A02 I
- Issued
- Sep 20, 2021
- Penalty
- Initial $2,653 · Current $1,857 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): Outside Exterior of Maintenance Shop: The orange 3 way adapter being used to power the grinder and fan had not been visually inspected before use for defects and was found with a broken ground pin in it. Employee(s) had used the grinder to grind worn mower reels and the fan was used for air circulation. Employee(s) were exposed to electrical and/or fire hazard(s).
Recent events (2)
- — I (S) $1857.1
- — Z (S) $2653
1910.242 B
- Issued
- Sep 20, 2021
- Penalty
- Initial $372 · Current $260 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: In the following locations, employee(s) used the compressed air line(s) for the air impact, air gun and cleaning purposes. The working air pressure in the air hose was greater than 90 PSI. a) Mechanical Tool Shed b) Maintenance Shop
Recent events (2)
- — I (O) $260.4
- — Z (O) $372
More inspections at Indian Canyons Golf Resort
View Indian Canyons Golf Resort's full OSHA safety record →
More inspections in this industry (NAICS 713910)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345487607.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.