GREENVILLE, PA —
OSHA Inspection: PENNEX ALUMINUM COMPANY LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PENNEX ALUMINUM COMPANY LLC in 93 WERNER RD., GREENVILLE, PA 16125 (NAICS 331314). OSHA activity number 345790034.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PENNEX ALUMINUM COMPANY LLC
- Site address
- 93 WERNER RD.
- City
- GREENVILLE
- State
- PA
- ZIP
- 16125
- Mailing
- 50 COMMUNITY ST., WELLSVILLE, PA 17365
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331314
- Employees
- 55
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.178 O01
- Issued
- Mar 21, 2022
- Abate by
- May 6, 2022
- Penalty
- Initial $7,396 · Current $7,396
General-duty citation text
1910.178(o)(1) The employer did not ensure that only stable or safely arranged loads were handled: a.) Pennex Aluminum Company, LLC; Furnace B - On or about 2/12/22 and at times prior thereto, a natural gas line was not protected against being struck by aluminum logs. A gas line that was attached to Furnace B and positioned next to the lay down table was struck by a large aluminum log when the log was being manipulated by the forklift. The gas line strike caused a fire when the natural gas was released. ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation. This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement. IN ADDITION, abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic, or video evidence or abatement or other written records.
Recent events (2)
- — I (O) $7396
- — Z (S) $7396
More inspections at Pennex Aluminum Company LLC
View Pennex Aluminum Company LLC's full OSHA safety record →
More inspections in this industry (NAICS 331314)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345790034.