Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PECHANGA RESORT AND CASINO

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of PECHANGA RESORT AND CASINO in 45000 PECHANGA PARKWAY, TEMECULA, CA 92592 (NAICS 721120). OSHA activity number 345804801.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pechanga Resort and Casino — free Get an email when a new federal OSHA severe-injury report for Pechanga Resort and Casino is published. One employer, no account, unsubscribe in one click.
Site address
45000 PECHANGA PARKWAY
City
TEMECULA
State
CA
ZIP
92592
Mailing
P.O. BOX 9041, TEMECULA, CA 92589
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
721120
Employees
3217
Ownership type
A

4 citations on file for this inspection.

1910.147 F03 I

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 21, 2022
Abate by
Jun 8, 2022
Penalty
Initial $7,044 · Current $4,226 Reduced
29 CFR  1910.147(f)(3)(i): A procedure was not utilized to afford the employees a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device when servicing and/or maintenance was performed by a crew, craft:  In December of 2021,  four employees performing maintenance on turbines in the Cogen plant did not each affix a personal lockout device to each source of energy, exposing employees to amputations and crush-by hazards.
Recent events (2)
  • — I (S) $4226.4
  • — Z (S) $7044

1910.151 C

Serious Gravity 5 2 instances 14 exposed
Issued
Apr 21, 2022
Penalty
Initial $7,044 · Current $4,226 Reduced

Hazardous substances 2310

29 CFR  1910.151(c):Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  The employer did not provide emergency shower or eyewash stations for the following:   Emergency Generator Room in Cogen Plant.  Employees were exposed to chemical burns of the eyes and skin while adding water to batteries.
Recent events (2)
  • — I (S) $4226.4
  • — Z (S) $7044

1910.215 A04

Serious Gravity 5 2 instances 1 exposed
Issued
Apr 21, 2022
Abate by
May 17, 2022
Penalty
Initial $7,044 · Current $4,226 Reduced
29 CFR  1910.215(a)(4):Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:  Landscaping Department.  Employees use a Jet 8 inch bench grinder model JBG-8A, S/N 14127999 to sharpen lawnmower blades.  (a) Landscaping Department.  The right hand work rest of the Jet 8 inch grinder model JBG-8A, S/N 14127999 was adjusted so that there was a 1 inch gap between the work rest and the abrasive wheel, exposing employees in the blacksmith area to caught-in and struck-by hazards;  (a) Landscaping Department.  The left hand work rest of the Jet 8 inch grinder model JBG-8A, S/N 14127999 was adjusted so that there was a 1 and 1/4 inch gap between the work rest and the abrasive wheel, exposing employees in the blacksmith area to caught-in and struck-by hazards.
Recent events (2)
  • — I (S) $4226.4
  • — Z (S) $7044

1910.147 C04 I

Deleted Repeat Gravity 5 1 instance 4 exposed
Issued
Apr 21, 2022
Abate by
Jun 30, 2022
Penalty
Initial $35,220 · Current $0 Reduced
29 CFR  1910.147(c)(4)(i):Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  Cogen Plant: In December of 2021, employee(s) were servicing the turbines  without a procedure developed, documented, and utilized for controlling all hazardous energy from rotating parts. Employees are exposed to entanglement hazards while performing maintenance work without equipment fully de-energized.  Pechanga Resort and Casino was previous cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.147(c)(4)(i), which was contained in OSHA inspection number 1453923, citation number 1 item number 2 and was affirmed as a final order on February 13, 2020, with respect to a workplace located at 45000 Pechanga Pkwy, Temecula, CA 92592.
Recent events (2)
  • — I (R) $0
  • — Z (R) $35220

View Pechanga Resort and Casino's full OSHA safety record →