TEMECULA, CA —
OSHA Inspection: PECHANGA RESORT AND CASINO
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of PECHANGA RESORT AND CASINO in 45000 PECHANGA PARKWAY, TEMECULA, CA 92592 (NAICS 713210). OSHA activity number 344060868.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PECHANGA RESORT AND CASINO
- Site address
- 45000 PECHANGA PARKWAY
- City
- TEMECULA
- State
- CA
- ZIP
- 92592
- Mailing
- P.O. BOX 9041, TEMECULA, CA 92589
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 713210
- Employees
- 4675
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.107 C02
- Issued
- Nov 29, 2019
- Abate by
- Jan 3, 2020
- Penalty
- Initial $13,260 · Current $0 Reduced
General-duty citation text
29 CFR 1910.107(c)(2): Spark producing equipment were located in the spraying area: Pechanga Casino & Hotel; elevator: A subcontracted employee used flammable liquids in conjunction with spark producing equipment while cleaning and refinishing the elevator. A spraying area without spark producing equipment was not provided by the correcting employer. The subcontracted employee was exposed to smoke inhalation and contact with fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $13260
1910.107 D02
- Issued
- Nov 29, 2019
- Abate by
- Jan 3, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(d)(2): Spraying area was not provided with mechanical ventilation adequate to remove flammable vapors or mists to a safe location and to confine and control combustible residues: Pechanga Casino & Hotel; elevator: A subcontracted employee used flammable liquids in conjunction with spark producing equipment while cleaning and refinishing the elevator with doors closed. A spraying area with adequate mechanical ventilation to remove flammable vapors or mists to a safe location was not provided by the correcting employer. The subcontracted employee was exposed to smoke inhalation and contact with fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 G08
- Issued
- Nov 29, 2019
- Abate by
- Jan 3, 2020
- Penalty
- Initial $13,260 · Current $0 Reduced
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work shift to employees when they were in their work area(s): Pechanga Casino & Hotel; elevator: A subcontracted employee used flammable liquids while cleaning and refinishing the elevator. The correcting employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that the safety data sheets were readily accessible during each work shift to employees when they were in their work area(s). The employees and subcontracted employee were exposed to smoke inhalation and contact with fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $13260
1910.1200 H03 III
- Issued
- Nov 29, 2019
- Abate by
- Jan 17, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(3)(iii): Employee training did not include the measures employees can take to protect themselves from chemical hazards, including specific procedures the employer had implemented to protect employees from exposure to hazardous chemicals, such as appropriate work practices, emergency procedures and personal protective equipment to be used: Pechanga Casino & Hotel; elevator: A subcontracted employee used flammable liquids while cleaning and refinishing the elevator with doors closed. The correcting employer observed the subcontracted employee use inappropriate work practices. The subcontracted employee did not receive effective training on the safety and health concerns such as reproductive hazards, flash point and flammability, or respiratory sensitivity by the controlling employer. The subcontracted employee was exposed to smoke inhalation and contact with fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Pechanga Resort and Casino
View Pechanga Resort and Casino's full OSHA safety record →
More inspections in this industry (NAICS 713210)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344060868.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.