Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JEIDA GUAM

Follow-up inspection · Safety discipline

On , OSHA opened a follow-up safety inspection of JEIDA GUAM in 1199 PALE SAN VITORES, TAMUNING, GU 96913 (NAICS 236220). OSHA activity number 346312556.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Jeida Guam — free Get an email when a new federal OSHA severe-injury report for Jeida Guam is published. One employer, no account, unsubscribe in one click.
Establishment
JEIDA GUAM
Site address
1199 PALE SAN VITORES
City
TAMUNING
State
GU
ZIP
96913
Mailing
P.O. BOX 11535, TAMUNING, GU 96931
Inspection type
Follow-up (F)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
236220
Employees
12
Ownership type
A

3 citations on file for this inspection.

1926.405 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 8, 2023
Penalty
Initial $2,678 · Current $2,678
29 CFR  1926.405(b)(2): All pull boxes, junction boxes, or fittings were not provided with covers:  Back wall electrical room: A pull box with a missing cover near the working table exposed employees to electrical hazards.
Recent events (1)
  • — Z (S) $2678

1926.403 B02

Repeat Gravity 1 1 instance 1 exposed
Issued
Mar 8, 2023
Penalty
Initial $5,357 · Current $5,357
29 CFR  1926.403(b)(2): 29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:  Men's bathroom: A Rigid Blower fan used for ventilation, and a Cooper light used for illumination were powered by a relocatable power tap connected in series with an extension cord to the power source. An employee was exposed to electrical and fire hazards.  Jeida Guam was previously cited for a violation of this Occupational Safety and Health Standard  29 CFR 1926.403(b)(2), which was contained in OSHA inspection number 1609746, citation number 1, item number 1 and was affirmed as a final order on October 14, 2022 with respect to a workplace located at the Sand Castle Hotel, Tamuning Guam.
Recent events (1)
  • — Z (R) $5357

1926.405 G02 IV

Other-than-serious 1 instance 1 exposed
Issued
Mar 8, 2023
Penalty
Initial $0 · Current $0
29 CFR  1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:  Male bathroom: The outer insulation to the blower fan flexible power cable was pulled from the plug exposing an employee to electrical hazards.
Recent events (1)
  • — Z (O) $0