TWENTYNINE PALMS MCB, CA —
OSHA Inspection: U.S. MARINE CORPS MCAGCC TWENTYNINE PALMS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of U.S. MARINE CORPS MCAGCC TWENTYNINE PALMS in PUBLIC WORKS DEPARTMENT - FACILITIES MAINTENANCE, BULIDINGS 1123, 1127, 1130,, TWENTYNINE PALMS MCB, CA 92278 (NAICS 561210). OSHA activity number 346862576.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- U.S. MARINE CORPS MCAGCC TWENTYNINE PALMS
- Site address
- PUBLIC WORKS DEPARTMENT - FACILITIES MAINTENANCE, BULIDINGS 1123, 1127, 1130,
- City
- TWENTYNINE PALMS MCB
- State
- CA
- ZIP
- 92278
- Mailing
- SAFETY DIVISON, BOX 788100, TWENTYNINE PALMS MCB, CA 92278
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561210
- Employees
- 96
- Ownership type
- D
Citations
13 citations on file for this inspection.
1910.157 E02
- Issued
- Sep 25, 2023
- Abate by
- Oct 30, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: On and/or before July 25, 2023, the fire extinguishers in the following locations had not been subjected to their annual and/or monthly maintenance check(s). This condition potentially exposed employee(s) to fire hazards. In the following location(s): a) Facilities Shop, Employee Breakroom, Bldg. 1123 b) Facilities Shop, Outside Employee Breakroom, Bldg. 1123 c) Welding Shop, Bldg. 1123 d) Sheet Metal Shop, Bldg. 1123
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A03 II
- Issued
- Sep 25, 2023
- Abate by
- Oct 10, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle. Facilities Shop, Bldg. 1123: On and/or before July 25, 2023, employee(s) used an 18" Metal/Wood Cutting Bandsaw to cut wood. The 18" Metal/Wood Cutting Bandsaw was not guarded to prevent employee(s) from having their hand(s), and/or finger(s) in the danger zone during operation. This condition potentially exposed employee(s) to amputation hazard(s).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 B
- Issued
- Sep 25, 2023
- Abate by
- Oct 5, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving. On and/or before July 25, 2023, employee(s) used multiple woodworking machinery and JET 15" Floor Drill Press machine(s) that were not securely anchored to the ground. This condition potentially exposed employee(s) to struck by, caught in between, and/or amputation hazard(s). In the following locations: a) Facilities Shop, Bldg. 1123, 4x8 Maverick Legacy Woodworking Machinery b) Facilities Shop, Bldg. 1123, JET 18" Metal/Wood Cutting Bandsaw c) Facilities Shop, Bldg. 1123, Marathon Electric MODL d) Welding Shop, Bldg. 1123, JET 15" Floor Drill Press machine e) Sheet Metal Shop, Bldg. 1123, JET 15" Floor Drill Press machine
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.215 B09
- Issued
- Sep 25, 2023
- Abate by
- Oct 5, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch. Welding Shop, Bldg. 1123: On and/or before July 25, 2023, the employer did not ensure that adjustable tongue for the left side grinding wheel for the Queen City Pedestal Grinder Model 11-F used by employee(s) was installed and adjusted closely to the wheel with a maximum opening of one fourth inch. Employee(s) were potentially exposed to projectile and/or amputation hazard(s).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B02
- Issued
- Sep 25, 2023
- Abate by
- Oct 20, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling. On and/or before July 25, 2023, multiple appliances/machines such as refrigerator, microwave and the 4x8 Maverick Legacy Woodworking Machinery were plugged into a relocatable power tap in which were not used according to listing and labeling instructions. This condition potentially exposed employee(s) to fire hazard(s). In the following locations: a) Paint Storage Room, MicroFridge with Safe Plug b) Paint Storage Room, Kenmore Microwave Oven c) Facilities Shop, Bldg.1123, 4x8 Maverick Legacy Woodworking Machinery d) Administrative offices, Bldg. 1130, Microfridge with Safe Plug
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G01 II
- Issued
- Sep 25, 2023
- Abate by
- Oct 20, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage. On and/or before July 25, 2023, the employer did not ensure at least 3 feet in front of the electrical panel was clear. The circuit breaker panel had multiple machinery and an OraJET Printable Vinyl Roll(s) obstructing the panel. This condition interferes with access and immediate shutdown of a circuit in the panel, particularly in the event of an emergency. This condition potentially exposed employee(s) to electrical shock and/or fire hazard(s). In the following location(s): a) Welding Shop, Bldg. 1123 b) Sign Shop
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G02 I
- Issued
- Sep 25, 2023
- Abate by
- Oct 5, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets or other forms of approved enclosures, or other means listed under this provision: On and/or before July 25, 2023, the employer did not ensure that exposed live wire(s) were enclosed. Flexible cords and cables were exposed and not protected from pinch points and/or projections. This condition potentially exposed employee(s) to electrical shock and/or fire hazard(s). In the following location(s): a) Welding Shop, Bldg. 1123 d) Sheet Metal Shop, Bldg. 1123
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B02 I
- Issued
- Sep 25, 2023
- Abate by
- Oct 5, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: Facilities Shop, Employee Breakroom, Bldg. 1123: On and/or before July 25, 2023, employee(s) used the Frigidaire refrigerator in the employee breakroom to store food and/or drinks. The energized electrical outlet was missing the protective faceplate. Employee(s) were potentially exposed to electrical shock and/or fire hazard(s).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Sep 25, 2023
- Abate by
- Oct 5, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: Paint Shop, Bldg. 1123: On and/or before July 25, 2023, flexible cords and/or cables were used as a source of permanent power for MicroFridge with Safe Plug Refrigerator. Employee(s) were potentially exposed to electrical shock and/or fire hazard(s).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV B
- Issued
- Sep 25, 2023
- Abate by
- Oct 10, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and/or cables were run through holes in walls, ceilings, or floors: On and/or before July 25, 2023, flexible cords and/or cables were run through holes in walls, ceilings and were used as a source of permanent power. Employee(s) were potentially exposed to electrical shock and/or fire hazard(s). In the following location(s): a) Paint Shop, Bldg. 1123. b) Facilities Shop, Bldg. 1123.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G02 III
- Issued
- Sep 25, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: Facilities Shop, Bldg. 1123: On and/or before July 25, 2023, employee(s) used the 4x8 Maverick Legacy Woodworking Machinery and the GBC Shredmaster 4220S did not have strain relief and had exposed wiring. This condition potentially exposed employee(s) to electrical shock and/or fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.37 A04
- Issued
- Sep 25, 2023
- Abate by
- Oct 5, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times. Facilities Shop, Employee Breakroom, Bldg. 1123: On and/or before July 25, 2023, a ceiling panel in the employee breakroom was missing. This condition would delay the activation of the sprinkler system(s) preventing a proper fire/smoke barrier and restricting the movement of smoke in accordance with NFPA 101 8.5.1. This condition potentially exposed employee(s) to fire and smoke inhalation hazard(s).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 C01
- Issued
- Sep 25, 2023
- Abate by
- Oct 5, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: On and/or before July 25, 2023, multiple fire extinguisher(s) were not mounted to the wall. Unmounted fire extinguisher(s) may cause a delayed response and/or inability to locate during an emergency. This condition potentially exposed employee(s) to fire and/or smoke inhalation hazards. In the following location(s): a) Facilities Shop, Employee Breakroom Bldg. 1123 b) Welding Shop, Bldg. 1123 c) Sheet Metal Shop, Bldg. 1123
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at U.S. Marine Corps Mcagcc Twentynine Palms
View U.S. Marine Corps Mcagcc Twentynine Palms's full OSHA safety record →
More inspections in this industry (NAICS 561210)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346862576.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.