Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S. MARINE CORPS MCAGCC TWENTYNINE PALMS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S. MARINE CORPS MCAGCC TWENTYNINE PALMS in BLDG 1584 4TH STREET, TWENTYNINE PALMS MCB, CA 92278 (NAICS 713950). OSHA activity number 346862527.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Marine Corps Mcagcc Twentynine Palms — free Get an email when a new federal OSHA severe-injury report for U.S. Marine Corps Mcagcc Twentynine Palms is published. One employer, no account, unsubscribe in one click.
Site address
BLDG 1584 4TH STREET
City
TWENTYNINE PALMS MCB
State
CA
ZIP
92278
Mailing
P.O BOX 788150, TWENTYNINE PALMS MCB, CA 92278
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
713950
Employees
9
Ownership type
D

5 citations on file for this inspection.

1910.159 C08 III

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 11, 2023
Abate by
Oct 5, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.159(c)(8)(iii): Sprinklers on automatic sprinkler systems were not protected from mechanical damage.  Pin-Setter Room: On and/or before July 24th, 2023,  multiple fire suppression sprinkler head(s) were missing cages and/or guards in low lying ceiling areas. Potential damage to sprinkle heads could prevent activation in the event of a fire.  This condition potentially exposed employee(s) to fire and/or laceration hazards.
Recent events (1)
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 11, 2023
Abate by
Oct 5, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  Pinsetter Area: On and/or before July 24th, 2023 employee(s) walked past the pin setter machines to service them during times of operation. The side(s) of the machines located at walkway isles were not guarded. This condition potentially exposed employee(s) to unguarded moving machine parts and/or amputation hazard(s).
Recent events (1)
  • — Z (S) $0

1910.212 A03 II

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 11, 2023
Abate by
Oct 27, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.212(a)(3)(ii): The  point of operation of machines whose operation exposed an employee to injury, was not guarded:  Maintenance Room: On and/or before July 24th, 2023,  the employer did not provide a method of guarding the Jet Drill Press. Employee(s) used the drills for bowling ball alterations. This condition potentially exposed employee(s) to the drill point of operation/nip points, drill bit breakage, contact with flying chips, rotating parts and/or entanglement.
Recent events (1)
  • — Z (S) $0

1910.303 B02

Serious Gravity 5 2 instances 2 exposed
Issued
Sep 11, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling.  On and/or before July 24th, 2023, multiple appliances/machines such as arcade video game and a microwave was plugged into a relocatable power tap in which were not used according to listing and labeling instructions. This condition potentially exposed employee(s) to electrical shock and/or fire hazard(s).  In the following location(s): a) Arcade Area b) Maintenance Room
Recent events (1)
  • — Z (S) $0

1910.37 A04

Other-than-serious 1 instance 1 exposed
Issued
Sep 11, 2023
Abate by
Oct 27, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times.  Bowling Floor: On and/or before July 24th, 2023, multiple ceiling tiles throughout the bowling floor had holes and/or were improperly installed. This condition would delay the activation of the sprinkler system(s) preventing a proper fire/smoke barrier and restricting the movement of smoke in accordance with NFPA 101 8.5.1. This condition potentially exposed employee(s) to fire and smoke inhalation hazard(s).
Recent events (1)
  • — Z (O) $0

View U.S. Marine Corps Mcagcc Twentynine Palms's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346862527.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.