Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CORRY FABRICATION, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CORRY FABRICATION, LLC in 21 MAPLE AVENUE, CORRY, PA 16407 (NAICS 332322). OSHA activity number 347296063.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Corry Fabrication, LLC — free Get an email when a new federal OSHA severe-injury report for Corry Fabrication, LLC is published. One employer, no account, unsubscribe in one click.
Site address
21 MAPLE AVENUE
City
CORRY
State
PA
ZIP
16407
Mailing
21 MAPLE AVENUE, CORRY, PA 16407
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
62
Ownership type
A

7 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 17, 2024
Abate by
Nov 12, 2024
Penalty
Initial $6,453 · Current $4,000 Reduced
29 CFR  1910.147(c)(4)(i):Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  A.) Corry Fabrication, LLC, on or about 2/22/24 and times prior thereto: Specific Lockout Tagout procedures were not developed for equipment including but limited to oven, crane, and laser.      ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $6453

1910.147 E03

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 17, 2024
Abate by
Nov 12, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.147(e)(3):Specific procedures and training that were developed, documented and incorporated into the employer's energy control program for removal of a lockout or tagout device under the direction of the employer when the authorized employee  A.) Corry Fabrication, LLC, on or about 2/22/24 and times prior thereto: employees periodically conducted service, maintenance, and repairs on equipment.  The energy control procedure developed for use during removal of a lockout device by someone other than the authorized employee who applied it situations, were not specific and/or require specific procedural steps prior to and after the removal of the lock.  Equipment includes but is not limited to  cranes, lasers, and hydraulic equipment.  ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 F02 I

Serious Gravity 5 1 instance 62 exposed
Issued
Jul 17, 2024
Abate by
Aug 12, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.147(f)(2)(i): When outside servicing personnel were engaged in activities in a facility, the onsite employer and the outside employer did not inform each other of their respective lockout or tagout procedures:   A.) Corry Fabrication, LLC, on or about 2/22/24 and times prior thereto: The employer periodically used outside contractors for servicing maintenance and repairs to equipment in the facility including but not limited to, the elevator and the burn off oven.  specific procedures were not developed and implemented for outside contractors performing lockout.     ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 17, 2024
Abate by
Nov 12, 2024
Penalty
Initial $9,680 · Current $4,000 Reduced
29 CFR  1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:   A.) Corry Fabrication, LLC, First Floor, on or about 2/22/24 and times prior thereto: The employer did not conduct periodic inspections for authorized employees.   ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement
Recent events (2)
  • — I (S) $4000
  • — Z (S) $9680

1910.147 C07 I

Serious Gravity 5 1 instance 62 exposed
Issued
Jul 17, 2024
Abate by
Aug 12, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(7)(i):The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees:  A.) Corry Fabrication, LLC, on or about 2/22/24 and times prior thereto: Employees conduct service and maintenance on equipment including but not limited to cranes, lasers, and hydraulic equipment.  The employer did not conduct Lockout Tagout/Hazardous Energy Control training with Authorized employees.   B.) Corry Fabrication, LLC, on or about 2/22/24 and times prior thereto: Employees work around equipment that requires periodic service and maintenance. The employer did not conduct Lockout Tagout/Hazardous Energy Control training with Affected employees.  ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.145 C03

Other-than-serious 1 instance 45 exposed
Issued
Jul 17, 2024
Abate by
Aug 12, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.145(c)(3):Safety instruction sign(s) were not used where there was a need for general instructions and suggestions relative to safety measure(s):  A.) Corry Fabrication, LLC, on or about 2/22/24 and times prior thereto: safety instruction signs not posted on the elevator to inform that no riders are permitted until the safety gate is added.    ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.147 C05 II

Other-than-serious 1 instance 62 exposed
Issued
Jul 17, 2024
Abate by
Aug 12, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(5)(ii): Lockout devices and tagout devices were utilized for other purposes than controlling energy:  A.) Corry Fabrication, LLC, on or about 2/22/24 and times prior thereto: Lockout devices were not distinguished from other devices in the workplace.  Other devices include but are not limited to locks to take equipment out of service. Red locks were used as both lockout devices and locks to take equipment out of service.       ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Corry Fabrication, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347296063.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.