Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CORRY FABRICATION, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CORRY FABRICATION, LLC in 21 MAPLE AVENUE, CORRY, PA 16407 (NAICS 332322). OSHA activity number 348104324.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Corry Fabrication, LLC — free Get an email when a new federal OSHA severe-injury report for Corry Fabrication, LLC is published. One employer, no account, unsubscribe in one click.
Site address
21 MAPLE AVENUE
City
CORRY
State
PA
ZIP
16407
Mailing
21 MAPLE AVENUE, CORRY, PA 16407
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Last modified
Data loaded
NAICS code
332322
Employees
65
Ownership type
A

5 citations on file for this inspection.

1910.303 B02

Serious Gravity 5 1 instance 10 exposed
Issued
Aug 25, 2025
Abate by
Sep 19, 2025
Penalty
Initial $7,035 · Current $4,600 Reduced
29 CFR  1910.303(b)(2):Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:   A.) Corry Fabrication, LLC, On or about 3/13/25 and times prior thereto: Knockout receptacle boxes were being used to power equipment including but not limited to portable welders.  The knockout box receptacle was located on the floor. Knockout Receptacle boxes are not listed and labeled for use on the floor and are required to be surface mounted.  ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $4600
  • — Z (S) $7035

1910.254 D09 III

Serious Gravity 5 2 instances 11 exposed
Issued
Aug 25, 2025
Abate by
Sep 19, 2025
Penalty
Initial $5,627 · Current $0 Reduced
29 CFR  1910.254(d)(9)(iii): Cables with damaged insulation or exposed bare conductors were not replaced:   A.) Corry Fabrication, LLC, On or about 3/13/25 and times prior thereto: Employees are using damaged cables for welding operations associated with equipment including but not limited to, Lincoln Electric 60-179 in the first-floor chip blaster area exposing employees to potential electrical hazards.  Insulation was stripped back from the wiring exposing the copper interior of the ground wire.   B.) Corry Fabrication, LLC, On or about 3/13/25 and times prior thereto: Employees are using damaged cables for welding operations associated with equipment including but not limited to, Lincoln Electric 60-960 in the first-floor welding cell exposing employees to potential electrical hazards.  Cords were wrapped in black electrical tape.   ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5627

1910.334 A02 II

Serious Gravity 1 1 instance 12 exposed
Issued
Aug 25, 2025
Abate by
Sep 19, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.334(a)(2)(ii):There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service:  A.) Corry Fabrication, LLC, On or about 3/13/25 and times prior thereto: extension cords were observed with electrical tape repairs. Damaged Electrical cords are used to power equipment including but not limited to, radios, and power tools  ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.332 B01

Serious Gravity 1 1 instance 12 exposed
Issued
Aug 25, 2025
Abate by
Sep 19, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.332(b)(1):Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments:  A.)	Corry Fabrication, LLC, On or about 3/13/25 and times prior thereto: Defective cords with tape repairs were observed.  Employees were not trained on the safety related work practices of 1910.334 associated with extension cords and flexible cords.  ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 D01 III

Other-than-serious 1 instance 15 exposed
Issued
Aug 25, 2025
Abate by
Oct 10, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form.   a.) Corry Fabrication, LLC, located at 21 Maple Ave, Corry, PA 16407, on or about 3/13/25, and times prior thereto: The employer did not evaluate respiratory hazards in areas where respirators are required to be worn.  Respirators were required in areas including but not limited to, sandblasting, powder coating, welding, lasers.   ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation.  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement. IN ADDITION, abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic, or video evidence or abatement or other written records.