Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GATTO INDUSTRIAL PLATERS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of GATTO INDUSTRIAL PLATERS, INC. in 4620 WEST ROOSEVELT ROAD, CHICAGO, IL 60644 (NAICS 332813). OSHA activity number 347670754.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Gatto Industrial Platers, INC. — free Get an email when a new federal OSHA severe-injury report for Gatto Industrial Platers, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4620 WEST ROOSEVELT ROAD
City
CHICAGO
State
IL
ZIP
60644
Mailing
4620 WEST ROOSEVELT ROAD, CHICAGO, IL 60644
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332813
Employees
155
Ownership type
A

3 citations on file for this inspection.

1910.106 D02 I

Serious Gravity 10 1 instance 1 exposed
Issued
Oct 22, 2024
Penalty
Initial $14,518 · Current $7,500 Reduced
29 CFR 1910.106(d)(2)(i): "General." Only approved containers and portable tanks shall be used. Metal containers and portable tanks meeting the requirements of and containing products authorized by chapter I, title 49 of the Code of Federal Regulations (regulations issued by the Hazardous Materials Regulations Board, Department of Transportation), shall be deemed to be acceptable.  (a) On or about July 29, 2024, the employer failed to provide an approved flammable and combustible liquid containers used for flammable liquids when transferring gasoline from an approved container to an unapproved container (plastic bucket), thereby exposing employees to hazards associated with fire.
Recent events (2)
  • — I (S) $7500
  • — Z (S) $14518

1910.334 A02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 22, 2024
Penalty
Initial $12,445 · Current $6,000 Reduced
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  a) On or about July 29, 2024, in the back-room storage area, the employer failed to ensure the extension cord attached to the 120-volt electrical pump, was visually inspected prior to use. The extension cord in use was missing the ground prong, thereby exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $6000
  • — Z (S) $12445

1910.334 D

Serious Gravity 10 1 instance 1 exposed
Issued
Oct 22, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.334(d): Occasional use of flammable or ignitable materials. Where flammable materials are present only occasionally, electric equipment capable of igniting them shall not be used, unless measures are taken to prevent hazardous conditions from developing. Such materials include, but are not limited to: flammable gases, vapors, or liquids; combustible dust; and ignitable fibers or flyings. Note: Electrical installation requirements for locations where flammable materials are present on a regular basis are contained in 1910.307. [55 FR 32016, Aug. 6, 1990; 55 FR 46054, Nov. 1, 1990]  a. On or about July 29, 2024, in the back-room storage area, the employer failed to provide an approved pump to transfer low flash point flammable liquids, thereby exposing employees to hazards associated with fire.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Gatto Industrial Platers, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347670754.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.