FRANKLIN, OH —
OSHA Inspection: DYNOS GROUP GMBH
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of DYNOS GROUP GMBH in 1000 ANDERSON STREET, FRANKLIN, OH 45005 (NAICS 322121). OSHA activity number 347704728.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DYNOS GROUP GMBH
- Site address
- 1000 ANDERSON STREET
- City
- FRANKLIN
- State
- OH
- ZIP
- 45005
- Mailing
- P.O. BOX 215, FRANKLIN, OH 45005
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 322121
- Employees
- 36
- Ownership type
- A
Citations
14 citations on file for this inspection.
1910.146 C07 I
- Issued
- Jan 14, 2025
- Abate by
- Jun 10, 2025
- Penalty
- Initial $15,970 · Current $9,582 Reduced
General-duty citation text
1910.146(c)(7)(i) If the permit space poses no actual or potential atmospheric hazards and if all hazards within the space are eliminated without entry into the space, the permit space may be reclassified as a non-permit confined space for as long as the non-atmospheric hazards remain eliminated. a) On or about 08/20/2024, Dynos did not certify the space was reclassified out of the permit required program.
Recent events (2)
- — I (S) $9582
- — Z (S) $15970
1910.146 D03
- Issued
- Jan 14, 2025
- Abate by
- Feb 10, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(d)(3): Develop and implement the means, procedures, and practices necessary for safe permit space entry operations, including, but not limited to, the following: (d)(3)(ii) Providing each authorized entrant or that employee's authorized representative with the opportunity to observe any monitoring or testing of permit spaces; (d)(3)(iii): Isolating the permit space (d)(3)(vi): Verifying that conditions in the permit space are acceptable for entry throughout the duration of an authorized entry. a) On or about 08/20/2024, the employer did not ensure implementation of the procedures for safe permit space entry operations for the tornado pulper such as providing each authorized entrant the opportunity to observe any monitoring or testing of permit spaces in that there was no monitoring or testing of the permit space's atmospheric content to include oxygen levels, isolating the permit space in that the whitewater return line did not have locks applied to the valves and was not double block and bled, blanked, blinded, or have a section of the pipe removed, and the conditions were not verified in the tornado pulper in that there was no monitoring or testing throughout the authorized entry of the tornado pulper.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.146 D04
- Issued
- Jan 14, 2025
- Abate by
- Feb 10, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(d)(4): Provide the following equipment (specified in paragraphs (d)(4)(i) through (d)(4)(ix) of this section) at no cost to employees, maintain that equipment properly, and ensure that employees use that equipment properly: (d)(4)(i): Testing and monitoring equipment needed to comply with paragraph (d)(5) of this section; (d)(4)(ii): Ventilating equipment needed to obtain acceptable entry conditions; (d)(4)(viii): Rescue and emergency equipment needed to comply with paragraph (d)(9) of this section, except to the extent that the equipment is provided by rescue services; a) On or about 08/20/2024, the employer did not ensure that employees used testing and monitoring equipment, ventilating equipment, and used adequate rescue equipment such as but not limited to a tripod retrieval system before entering the permit required confined space of the tornado pulper.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.146 D05
- Issued
- Jan 14, 2025
- Abate by
- Feb 3, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(d)(5):Evaluate permit space conditions as follows when entry operations are conducted: (d)(5)(i): Test conditions in the permit space to determine if acceptable entry conditions exist before entry is authorized to begin, except that, if isolation of the space is infeasible because the space is large or is part of a continuous system (such as a sewer), pre-entry testing shall be performed to the extent feasible before entry is authorized and, if entry is authorized, entry conditions shall be continuously monitored in the areas where authorized entrants are working; (d)(5)(ii): Test or monitor the permit space as necessary to determine if acceptable entry conditions are being maintained during the course of entry operations; and (d)(5)(iv): Provide each authorized entrant or that employee's authorized representative an opportunity to observe the pre-entry and any subsequent testing or monitoring of permit spaces a) On or about 08/20/2024, employer did not ensure that the requirements for entry under (d)(5)(iv) through (d)(5)(iv) to check the atmospheric conditions were conducted and entry conditions acceptable before employees entered the 9' tornado pulper to replace equipment.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.146 D09
- Issued
- Jan 14, 2025
- Abate by
- Feb 3, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(d)(9): Develop and implement procedures for summoning rescue and emergency services, for rescuing entrants from permit spaces, for providing necessary emergency services to rescued employees, and for preventing unauthorized personnel from attempting a rescue; a) On or about 08/20/2024, the employer did not implement adequate rescue and emergency services for employees entering a permit required confined space, the tornado pulper, in that emergency services were not on standby and employees were tied off to guard rails surrounding the tornado tub and not an emergency rescue and retrieval system such as but not limited to a tripod.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.146 C07 I
- Issued
- Jan 14, 2025
- Abate by
- Jun 10, 2025
- Penalty
- Initial $15,970 · Current $0 Reduced
General-duty citation text
1910.146(c)(7)(i) If the permit space poses no actual or potential atmospheric hazards and if all hazards within the space are eliminated without entry into the space, the permit space may be reclassified as a non-permit confined space for as long as the non-atmospheric hazards remain eliminated. a) On or about 08/20/2024, Dynos did not certify the space was reclassified out of the permit required program.
Recent events (2)
- — I (S) $0
- — Z (S) $15970
1910.146 C07 III
- Issued
- Jan 14, 2025
- Abate by
- Jun 10, 2025
- Penalty
- Initial $15,970 · Current $0 Reduced
General-duty citation text
1910.146(c)(7)(iii) The employer shall document the basis for determining that all hazards in a permit space have been eliminated, through a certification that contains the date, the location of the space, and the signature of the person making the determination. The certification shall be made available to each employee entering the space or to that employee's authorized representative. a) On or about 08/20/2024, Dynos did not certify the space was reclassified out of the permit required program.
Recent events (2)
- — I (S) $0
- — Z (S) $15970
1910.146 I07
- Issued
- Jan 14, 2025
- Abate by
- Jun 10, 2025
- Penalty
- Initial $15,970 · Current $9,582 Reduced
General-duty citation text
29 CFR 1910.146(i)(7): Summon rescue and other emergency services as soon as the attendant determines that authorized entrants may need assistance to escape from permit space hazards; a) On or about 08/20/2024, the employer did not ensure that the attendant was able to summon rescue and emergency services in a timely manner for employees entering the tornado pulper as soon as authorized entrants may have needed assistance.
Recent events (2)
- — I (S) $9582
- — Z (S) $15970
1910.146 J04
- Issued
- Jan 14, 2025
- Abate by
- Jun 10, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(j)(4): Verifies that rescue services are available and that the means for summoning them are operable; a) On or about 08/20/2024, the employer did not ensure that prior to entry into the 9' tornado tub that the entry supervisor had verified and documented that rescue services were available.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.146 K01
- Issued
- Jan 14, 2025
- Abate by
- Jun 10, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(k)(1):An employer who designates rescue and emergency services, pursuant to paragraph (d)(9) of this section, shall: (k)(1)(i) Evaluate a prospective rescuer's ability to respond to a rescue summons in a timely manner, considering the hazard(s) identified; a) On or about 08/20/2024, the employer did not ensure that any designated rescue and emergency services had the ability to respond to a rescue summon for an incident in the tornado pulper.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C04 II
- Issued
- Jan 14, 2025
- Abate by
- Jun 10, 2025
- Penalty
- Initial $15,970 · Current $3,194 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii):The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following: (c)(4)(ii)(B): Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy; (c)(4)(ii)(C): Specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them; and (c)(4)(ii)(D)Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures. a) On or before 08/20/2024, the employer did not ensure that the LOTO procedures titled "tornado lockout" for the tornado pulper specified the steps for isolating the tornado pulper from the whitewater feedline by means such as double block and bleed, blanking, blinding, or removing a section of the pipe, and ensuring that lockout devices were placed on the valves to prevent the pulper from being filled with water with employees inside it. The procedures also did not specify to place a lock on the disconnect for the whitewater feed line in the refiner room. The procedures also did not specify how to test the whitewater feed line to ensure all the water had been drained from the pipe. b) On or about 10/28/24, the employer did not ensure that the newly established LOTO procedures titled " Cheney Dynos, Inc. Specific LOTO Instructions" with equipment ID for the tornado which is the tornado pulper specified the steps for isolating the tornado pulper from the whitewater feedline by means such as double block and bleed, blanking, blinding, or removing a section of the pipe, and ensuring that lockout devices were placed on the valves to prevent the pulper from being filled with water with employees inside it. The procedures also did not specify to place a lock on the disconnect for the whitewater feed line in the refiner room. The procedures also did not specify how to test the whitewater feed line to ensure all the water had been drained from the pipe. c) On or about 01/13/2024, the employer did not ensure that the revised LOTO procedures titled " Tornado LOTO procedures- NEW" that was the revised version of the " Cheney Dynos, Inc. Specific LOTO Instructions" with equipment ID for the tornado which is the tornado pulper specified the steps for isolating the tornado pulper from the whitewater feedline by means such as double block and bleed, blanking, blinding, or removing a section of the pipe, to prevent the pulper from being filled with water with employees inside it. The procedures also did not specify to place a lock on the disconnect for the whitewater feed line in the refiner room. The procedures also did not specify how to test the whitewater feed line to ensure all the water had been drained from the pipe.
Recent events (2)
- — I (O) $3194
- — Z (S) $15970
1910.147 C06 I
- Issued
- Jan 14, 2025
- Abate by
- Jun 10, 2025
- Penalty
- Initial $15,970 · Current $3,194 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. a) On or before 08/20/2024, the employer did not conduct an annual periodic inspection of the energy control procedures for the tornado pulper to ensure the procedures were adequate for isolating the tornado pulper from the whitewater feed line that had the potential to pour water into the tornado pulper where employees were working.
Recent events (2)
- — I (O) $3194
- — Z (S) $15970
1910.147 C07 I
- Issued
- Jan 14, 2025
- Abate by
- Jun 10, 2025
- Penalty
- Initial $15,970 · Current $3,194 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i):The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following: (c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control. a) On or about the 08/20/2024, the employer did not ensure that authorized employees were adequately trained on the methods and means for locking out a whitewater feed line that fills water into a tornado tub by means such as but not limited to blanking, blinding, or removing a section of the pipe, and locks were not applied on the valves for the line.
Recent events (2)
- — I (O) $3194
- — Z (S) $15970
1910.147 D
- Issued
- Jan 14, 2025
- Abate by
- Feb 10, 2025
- Penalty
- Initial $15,970 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence: (d)(1) Preparation for shutdown. Before an authorized or affected employee turns off a machine or equipment, the authorized employee shall have knowledge of the type and magnitude of the energy, the hazards of the energy to be controlled, and the method or means to control the energy. (d)(3) Machine or equipment isolation. All energy isolating devices that are needed to control the energy to the machine or equipment shall be physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s). (d)(4) Lockout or tagout device application. (d)(4)(i) Lockout or tagout devices shall be affixed to each energy isolating device by authorized employees. (d)(5)Stored energy. (d)(5)(i) Following the application of lockout or tagout devices to energy isolating devices, all potentially hazardous stored or residual energy shall be relieved, disconnected, restrained, and otherwise rendered safe. a)On or about 08/20/2024, the employer did not ensure that employees locking out the tornado pulper to retrieve a tornado tackle from inside the pulper followed steps d1, d3, d4i, and d5i was isolated from the whitewater feed line that fills the tub with water by means such as but not limited to blanking, blinding or removing a section of the pipe, did not have lockout devices applied to the valves.
Recent events (2)
- — I (S) $0
- — Z (S) $15970
More inspections at Dynos Group Gmbh
View Dynos Group Gmbh's full OSHA safety record →
More inspections in this industry (NAICS 322121)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347704728.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.