Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DYNOS GROUP GMBH

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DYNOS GROUP GMBH in 1000 ANDERSON STREET, FRANKLIN, OH 45005 (NAICS 322121). OSHA activity number 347800633.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dynos Group Gmbh — free Get an email when a new federal OSHA severe-injury report for Dynos Group Gmbh is published. One employer, no account, unsubscribe in one click.
Establishment
DYNOS GROUP GMBH
Site address
1000 ANDERSON STREET
City
FRANKLIN
State
OH
ZIP
45005
Mailing
P.O. BOX 215, FRANKLIN, OH 45005
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
322121
Employees
36
Ownership type
A

6 citations on file for this inspection.

1910.23 B10

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 17, 2025
Abate by
Feb 13, 2025
Penalty
Initial $7,282 · Current $4,369 Reduced
1910.23(b): General requirements for all ladders. The employer must ensure:  (9) Ladders are inspected before initial use in each work shift, and more frequently as necessary, to identify any visible defects that could cause employee injury;  (10) Any ladder with structural or other defects is immediately tagged "Dangerous: Do Not Use" or with similar language in accordance with §1910.145 and removed from service until repaired in accordance with §1910.22(d), or replaced;  a) On or about 08/22/2024, the employer did not ensure that the Werner 12 foot ladder used to access the fan located above the maintenance shop was free of defects such as: the bent side rail at the 3rd and 4th rung nor was the ladder tagged and removed from service.
Recent events (2)
  • — I (S) $4369.2
  • — Z (S) $7282

1910.23 C11

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 17, 2025
Abate by
Feb 13, 2025
Penalty
Initial $12,744 · Current $0 Reduced
29 CFR  1910.23(c)(11): Portable ladders used to gain access to an upper landing surface have side rails that extend at least 3 feet (0.9 m) above the upper landing surface (see Figure D-1);  a) On or before 08/22/2024, the employer did not ensure that the 12 foot Werner ladder being used in the loft of the maintenance shop was extended 3 feet above the edge of the opening that employees were using to access the platform to reach the exhaust fan located on the loft landing.
Recent events (2)
  • — I (S) $0
  • — Z (S) $12744

1910.28 B03 I

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Jan 17, 2025
Abate by
Feb 13, 2025
Penalty
Initial $12,744 · Current $0 Reduced
29 CFR  1910.28(b)(3)(i): Holes. The employer must ensure: (i) Each employee is protected from falling through any hole (including skylights) that is 4 feet (1.2 m) or more above a lower level by one or more of the following:  (b)(3)(i)(B) Guardrail systems; (b)(3)(i)(C) Travel restraint systems; or (b)(3)(i)(D) Personal fall arrest systems.  a) On or about 09/07/2024, the employer did not ensure that prior to removing the cover for the 9 foot rotary 4 hole located in the cotton room, was protected by one or more of the following: a guardrail system, travel restraint system, or personal fall arrest systems to prevent exposure to a fall hazard for all employees working in the area.
Recent events (2)
  • — I (S) $0
  • — Z (S) $12744

1910.30 A03

Serious Gravity 10 1 instance 8 exposed
Issued
Jan 17, 2025
Abate by
Mar 10, 2025
Penalty
Initial $12,744 · Current $7,646 Reduced
29 CFR  1910.30(a)(3): The employer must train each employee in at least the following topics:  (i) The nature of the fall hazards in the work area and how to recognize them; (ii)The procedures to be followed to minimize those hazards;  a) On or about 08/22/2024, the employer did not ensure that employees were adequately trained to ensure the 12 foot Werner ladder being used in the loft of the maintenance shop was extended 3 feet above the edge of the opening that employees were using to access the exhaust fan located on the loft landing, nor to inspect for damage on the 12 foot Werner ladder side rails that was bent.  b) On or about 09/07/2024, the employer did not ensure that employees were adequately trained on the procedures for when to wear fall protection while moving conveyor heads over holes that pour material in the rotaries.  Dynos Group GMBH was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.30(a)(3), which was contained in OSHA inspection number 1682064, citation number 1, item number 3, group letter c, and was affirmed as a final order on 11/16/2023, with respect to a workplace located at 1000 Anderson Street, Franklin, OH 45005.
Recent events (2)
  • — I (S) $7646.4
  • — Z (S) $12744

1910.145 A01

Serious Gravity 5 1 instance 8 exposed
Issued
Jan 17, 2025
Abate by
Feb 13, 2025
Penalty
Initial $9,104 · Current $0 Reduced
29 CFR  1910.145(a)(1):These specifications apply to the design, application, and use of signs or symbols (as included in paragraphs (c) through (e) of this section) that indicate and, insofar as possible, define specific hazards that could harm workers or the public, or both, or to property damage. These specifications are intended to cover all safety signs except those designed for streets, highways, and railroads. These specifications do not apply to plant bulletin boards or to safety posters.  a) On or about 09/07/2024, the employer did not ensure that signs or symbols that defined specific hazards to warn workers in the cotton room of that hazards from the open rotarties in that caution signs were not utilized around the openings where the conveyors were located to prevent employees from falling into the rotaries.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9104

1910.29 E02

Deleted Repeat Gravity 10 1 instance 8 exposed
Issued
Jan 17, 2025
Abate by
Feb 13, 2025
Penalty
Initial $25,487 · Current $0 Reduced
29 CFR  1910.29(e)(2): Covers. Is secured to prevent accidental displacement.   a) On or about 09/07/2024, in the Cotton Room at rotary #4, the employer did not ensure that the plywood cover over the floor holes at the rotaries were secured to prevent accidental displacement in that the bolts did not secure the cover in place as employees were able to lift the covers without removing any bolts.   Dynos Group GMBH was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.29(e), which was contained in OSHA inspection number 1682064, citation number 1, item number 3, group letter b, and was affirmed as a final order on 11/16/2023, with respect to a workplace located at 1000 Anderson Street, Franklin, OH 45005.
Recent events (2)
  • — I (R) $0
  • — Z (R) $25487

View Dynos Group Gmbh's full OSHA safety record →