PITI, GU —
OSHA Inspection: CABRAS MARINE CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CABRAS MARINE CORPORATION in 178 INDUSTRIAL AVE, PITI, GU 96915 (NAICS 336611). OSHA activity number 348233750.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CABRAS MARINE CORPORATION
- Site address
- 178 INDUSTRIAL AVE
- City
- PITI
- State
- GU
- ZIP
- 96915
- Mailing
- 178 INDUSTRIAL AVE, PITI, GU 96915
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336611
- Employees
- 280
- Ownership type
- A
Citations
13 citations on file for this inspection.
1910.305 G01 IV A
- Issued
- Jun 23, 2025
- Abate by
- Aug 8, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a. Structural Shop: Welding machines were connected to temporary fuse boxes that were powered by flexible electrical cords that were run from the wall mounted breaker panel to the temporary fuse boxes in the middle of the shop. Employees were exposed to electrical hazards. b. Structural Shop: Breaker panels on the wall were powered by flexible cord running through the wall to the breaker panels in the mechanics' shop. Employees were exposed to electrical hazards. c. Paint Booth: Temporary lighting used in the paint storage container was powered by temporary flexible cord that was connected to a nearby building's electrical panel. Employees were exposed to electrical hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 A02 X
- Issued
- Jun 23, 2025
- Abate by
- Aug 8, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points. a. Machine Shop: The conduit was pulled away from one of the electrical boxes for the Yamazaki Lathe, exposing insulated conductors. Employee were exposed to electrical hazards. b. Structural Shop: Flexible cord which connected the wall mounted panel boxes to power was run through a cut out in the corrugated metal wall. Employees were exposed to electrical hazards. c. Paint Booth: Flexible cord, not protected from damage, which powered the spider box used as the temporary power source for the paint booth, was run for great lengths, over a pile of accumulated shop trash, connected to an electrical panel in another building. Employees were exposed to electrical hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.184 C01
- Issued
- Jun 23, 2025
- Penalty
- Initial $35,465 · Current $30,145 Reduced
General-duty citation text
29 CFR 1910.184(c)(1): Sling(s) that were damaged or defective were used: Machine Shop: The synthetic sling used to hold a forklift counterweight was ripped and frayed. Employees were exposed to struck-by hazards. The Cabras Marine Corporation was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1538905, citation number 1, item number 1b and was affirmed as a final order on 10/28/2021, with respect to a workplace located at 178 Industrial Ave.
Recent events (2)
- — I (R) $30145
- — Z (R) $35465
1910.184 C14
- Issued
- Jun 23, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.184(c)(14): Sling(s) were used without having affixed and legible identification markings: Machine Shop: The counterweight of a forklift was suspended using a synthetic sling whose label was illegible. Employees were exposed to struck by hazards. The Cabras Marine Corporation was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1538905, citation number 1, item number 1a and was affirmed as a final order on 10/28/2021, with respect to a workplace located at 178 Industrial Ave.
Recent events (2)
- — I (R) $0
- — Z (R) $0
1910.212 A01
- Issued
- Jun 23, 2025
- Penalty
- Initial $35,465 · Current $30,145 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a. Machine Shop: A Yamazaki Lathe used by employees for part repair and fabrication was equipped with a chuck guard that was broken and did not cover the lathe's chuck. Employees were exposed to rotating part hazards. b. Machine Shop: A Cleereman milling machine was used by employees for part repair and fabrication was not equipped with a chuck guard. Employees were exposed to rotating part hazards. c. Shore Support Shop: A Tongil Lathe was used by employees for part repair and fabrication was not equipped with a chuck guard. Employees were exposed to rotating part hazards. The Cabras Marine Corporation was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 1538905, citation number 1, item number 2and was affirmed as a final order on 10/28/2021, with respect to a workplace located at 178 Industrial Ave.
Recent events (2)
- — I (R) $30145
- — Z (R) $35465
1910.212 A03 II
- Issued
- Jun 23, 2025
- Penalty
- Initial $59,115 · Current $50,242 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): Structural Shop: The Accupress Press Brake was not guarded to prevent employees from having any part of their body in danger zones during operating cycles. Employees were exposed to amputation hazards. The Cabras Marine Corporation was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1538905, citation number 1, item number 3 and was affirmed as a final order on 10/28/2021, with respect to a workplace located at 178 Industrial Ave.
Recent events (2)
- — I (R) $50242
- — Z (R) $59115
1910.157 E03
- Issued
- Jun 23, 2025
- Abate by
- Jul 3, 2025
- Penalty
- Initial $472 · Current $401 Reduced
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: Machine Shop: The portable fire extinguisher available to employees for fighting incipient fires was not checked annually. Employees were exposed to fire hazards. The Cabras Marine Corporation was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1538905, citation number 2, item number 3and was affirmed as a final order on 10/28/2021, with respect to a workplace located at 178 Industrial Ave.
Recent events (2)
- — I (R) $401
- — Z (R) $472
1910.215 B09
- Issued
- Jun 23, 2025
- Penalty
- Initial $472 · Current $401 Reduced
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: Machine Shop: A bench grinder used by employees to clean and repair parts had two wheels with tongue guards that were set greater than one fourth of an inch from the wheel. Employees were exposed to struck-by hazards. The Cabras Marine Corporation was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1538905, citation number 1, item number 4 a and was affirmed as a final order on 10/28/2021, with respect to a workplace located at 178 Industrial Ave.
Recent events (2)
- — I (R) $401
- — Z (R) $472
1910.253 B04 III
- Issued
- Jun 23, 2025
- Penalty
- Initial $472 · Current $401 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet: Structural Shop: Oxygen and Acetylene cylinders that were not in use were stored together. Employees were exposed to fire hazards. The Cabras Marine Corporation was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number1538905, citation number 1, item number 5 and was affirmed as a final order on 10/28/2021, with respect to a workplace located at 178 Industrial Ave.
Recent events (2)
- — I (R) $401
- — Z (R) $472
1910.305 B01 II
- Issued
- Jun 23, 2025
- Penalty
- Initial $472 · Current $401 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: Structural Shop: Two breaker boxes behind the air compressor, including (1) Main Bkr #7, had knockouts missing, exposing live wires. Employees were exposed to electrical hazards. The Cabras Marine Corporation was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1538905, citation number 1, item number 6 and was affirmed as a final order on 10/28/21, with respect to a workplace located at 178 Industrial Ave.
Recent events (2)
- — I (R) $401
- — Z (R) $472
1910.219 D01
- Issued
- Jun 23, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): Shore Support Shop: There was an unguarded pulley exposed by a missing panel at the floor level on the Tongil lathe. Employees were exposed to caught-in and rotating parts hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 B02
- Issued
- Jun 23, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a. Structural Shop: A Relocatable Power Tap was used to power a shop fan and a portable grinder, used in a series or "daisy chained" with an extension cord. Employees were exposed to electrical and fire hazards. b. Shore Support Shop: A Relocatable Power Tap was used to power a microwave and water cooler. Employees were exposed to electrical and fire hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G02 III
- Issued
- Jun 23, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: Structural Shop: An extension cord to a fan had a cord covering that was pulled away from the plug on both sides of the cord, revealing insulated conductors in two places. Employees were exposed to electrical hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Cabras Marine Corporation
View Cabras Marine Corporation's full OSHA safety record →
More inspections in this industry (NAICS 336611)
More inspections in GU
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348233750.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.