CRANSTON, RI —
OSHA Inspection: STONE DEPOT OF RHODE ISLAND, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of STONE DEPOT OF RHODE ISLAND, INC. in 940 WELLINGTON AVENUE 950 WELLINGTON AVENUE, CRANSTON, RI 02910 (NAICS 327991). OSHA activity number 348245309.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STONE DEPOT OF RHODE ISLAND, INC.
- Site address
- 940 WELLINGTON AVENUE 950 WELLINGTON AVENUE
- City
- CRANSTON
- State
- RI
- ZIP
- 02910
- Mailing
- 940 WELLINGTON AVENUE, CRANSTON, RI 02910
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327991
- Employees
- 15
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.36 B01
- Issued
- Aug 25, 2025
- Abate by
- Oct 9, 2025
- Penalty
- Initial $5,064 · Current $3,545 Reduced
General-duty citation text
29 CFR 1910.36(b)(1): At least two exit routes were not available in the workplace to permit prompt evacuation of employees and other building occupants during an emergency, except as allowed in paragraph (b)(3) of this section. The exit routes must be located as far away as practical from each other so that if one exit route is blocked by fire or smoke, employees can evacuate using the second exit route. a) Building 950: On or about May 14, 2025, the employer did not ensure that at lease two exit routes were readily accessible for employee use, in the event of an emergency.
Recent events (2)
- — I (S) $3544.8
- — Z (S) $5064
1910.37 B02
- Issued
- Aug 25, 2025
- Abate by
- Oct 9, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit". a) Stone Shop building 950: On or about May 14, 2025, the employer did not ensure emergency exits were visibly marked by an 'Exit' sign.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B01
- Issued
- Aug 25, 2025
- Abate by
- Oct 9, 2025
- Penalty
- Initial $3,618 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees. a) Quarrying: On or about May 14, 2025, and times prior, the employer exposed employees to electrical hazards each time it rained, in that rain would drip into the electrical panel and pool on the ground just in front of the panel where employees were required to walk near and re-energize the breakers.
Recent events (2)
- — I (S) $0
- — Z (S) $3618
1910.334 B02
- Issued
- Aug 25, 2025
- Abate by
- Oct 9, 2025
- Penalty
- Initial $4,341 · Current $3,039 Reduced
General-duty citation text
29 CFR 1910.334(b)(2): The repetitive manual reclosing of circuit breakers or reenergizing electric power and lighting circuits through replaced fuses was not prohibited. a) Quarrying: On or about May 14, 2025, and times prior, the employer allowed employees to reenergize a circuit breaker each time it tripped without determining why it was tripping.
Recent events (2)
- — I (S) $3038.7
- — Z (S) $4341
1910.132 D01
- Issued
- Aug 25, 2025
- Abate by
- Oct 9, 2025
- Penalty
- Initial $406 · Current $284 Reduced
General-duty citation text
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE). a) Jobsite: On or about May 14, 2025, the employer did not conduct a hazard assessment to determine the appropriate level of personal protective equipment required for employees working with chemicals in the workplace.
Recent events (2)
- — I (O) $284.2
- — Z (O) $406
1910.141 A05
- Issued
- Aug 25, 2025
- Abate by
- Oct 9, 2025
- Penalty
- Initial $406 · Current $284 Reduced
General-duty citation text
29 CFR 1910.141(a)(5): A continuing and effective extermination program was not instituted where rodents, insects, or other vermin were detected. a) Stone Fabrication: On or about May 14, 2025, an enclosed workplace was not adequately maintained with a continuing and effective extermination program to prevent the harborage of rodents.
Recent events (2)
- — I (O) $284.2
- — Z (O) $406
1910.147 C07 I B
- Issued
- Aug 25, 2025
- Abate by
- Oct 9, 2025
- Penalty
- Initial $406 · Current $284 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure. a) Jobsite: On or about May 14, 2025, the employer did not provide lockout tagout training to all affected employees.
Recent events (2)
- — I (O) $284.2
- — Z (O) $406
1910.157 C04
- Issued
- Aug 25, 2025
- Abate by
- Oct 9, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(4): Portable fire extinguishers were not maintained in a fully charged and operable condition. a) Quarrying: On or about May 14, 2025, the employer did not ensure a fire extinguisher was fully charged and in operable condition, when placed in its designated location.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.178 L06
- Issued
- Aug 25, 2025
- Abate by
- Oct 9, 2025
- Penalty
- Initial $406 · Current $284 Reduced
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l). a) Jobsite: On or about May 14, 2025, the employer did not ensure that each operator had been trained, evaluated, and certified to operate a powered industrial truck.
Recent events (2)
- — I (O) $284.2
- — Z (O) $406
1910.305 G01 IV A
- Issued
- Aug 25, 2025
- Abate by
- Oct 9, 2025
- Penalty
- Initial $406 · Current $284 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure. a) Quarrying: On or about May 14, 2025, a flexible cord was used as a substitute for fixed wiring to energize a saw and fan.
Recent events (2)
- — I (O) $284.2
- — Z (O) $406
More inspections at Stone Depot of Rhode Island, INC.
View Stone Depot of Rhode Island, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 327991)
More inspections in RI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348245309.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.