OSHA Injury Report: Ocala LG

Injury · Days away from work

On , an injury at Ocala LG in Ocala, FL 34474 resulted in days away from work. Employee was tempering Technician in manufacturing.

Establishment
Ocala LG
Parent company
Cardinal LG
Street
1300 SW 44th Ave
City
Ocala
State
FL
ZIP
34474
On-site location
Seaming Table
Outcome
Days away from work (code 2)
Type
Injury (code 1)
Days away from work
3

Seaming glass

Around [REDACTED] the injured employee was seaming glass with the other coworkers. The work order was called for 4.7 glass in thickness. [REDACTED] was performing his task on the seamer [REDACTED] 8. His duties were to receive glass from the cutting table operator then proceed to seam two sides of the glass and pass it to the next seamer 29-Lewis [REDACTED] to seam the other two sides who was working on the [REDACTED] 9. At [REDACTED] [REDACTED] finished the two sides on a glass and passed it to [REDACTED]. At this point [REDACTED] was facing and talking with [REDACTED] and not paying attention to the other piece of glass that the table operator had already sent to him. This short time of distraction caused the piece of glass to run across the whole ball-table without the employee s attention and fall down behind where [REDACTED] was located causing the piece of glass to break and cause a laceration on [REDACTED] s calf.

Puncture-Hole Made w Sharp or Pointed Object Cut

Glass

Puncture Hole Made w Sharp or Pointed Object Cut to Left Leg caused by Glass

Job description
Tempering Technician
SOC code
9999 — Uncoded
NAICS code
327215 — Manufacturing
NAICS vintage
2022
Avg employees
359
Total hours worked
659082
EIN
411989305
Establishment ID
726091
Employer case #
IN-2023061
Date of incident
Shift started
6:00:00.000
Time of incident
12:01:00.000
Submitted
06FEB24:17:40:00

Data from OSHA ITA Form 300/301 electronic submissions, filing year unspecified. ITA Case Detail records are establishment-reported submissions, not OSHA inspections — no per-record IMIS deep link exists.