AVON LAKE, OH —
OSHA Inspection: PERRY FIBERGLASS PRODUCTS, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of PERRY FIBERGLASS PRODUCTS, INC. in 33660 PIN OAK PARKWAY, AVON LAKE, OH 44012 (NAICS 326199). OSHA activity number 339585036.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PERRY FIBERGLASS PRODUCTS, INC.
- Site address
- 33660 PIN OAK PARKWAY
- City
- AVON LAKE
- State
- OH
- ZIP
- 44012
- Mailing
- 33660 PIN OAK PKWY., AVON LAKE, OH 44012
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 68
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.134 E01
- Issued
- Jul 23, 2014
- Penalty
- Initial $2,310 · Current $1,155 Reduced
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a. Perry Fiberglass Products, Inc. - Avon Lake, Ohio: On or about February 13, 2014, the employer did not ensure that employees received a medical evaluation prior to providing a respirator for voluntary use. Employees in Plant 2 utilized a half face tight fitting respirator that can place a burden on an employee's cardiovascular and respiratory systems. b. Perry Fiberglass Products, Inc. - Avon Lake, Ohio: On or about February 13, 2014, the employer did not ensure that employees received a medical evaluation prior to providing a respirator for voluntary use. Employees laying fiberglass in Plant 1 utilized a half face tight fitting respirator that can place a burden on an employee's cardiovascular and respiratory systems.
Recent events (2)
- — I (S) $1155
- — Z (S) $2310
1910.146 C01
- Issued
- Jul 23, 2014
- Abate by
- Aug 8, 2014
- Penalty
- Initial $2,310 · Current $1,155 Reduced
General-duty citation text
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces: a. Perry Fiberglass Products, Inc. - Avon Lake, Ohio: On or about February 13, 2013, the employer did not perform an evaluation of the workplace to determine if permit-required confined spaces were present before employees entered the space of a fabricated tank(s) where the space and atmosphere would classify the space as a permit-required confined space.
Recent events (2)
- — I (S) $1155
- — Z (S) $2310
1910.146 C04
- Issued
- Jul 23, 2014
- Abate by
- Aug 8, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(c)(4): When the employer decided that its employees would enter permit spaces, the employer did not develop and implement a written permit space entry program that complied with 29 CFR 1910.146: a. Perry Fiberglass Products, Inc. - Avon Lake, Ohio: The employer did not implement a written permit space program which protected employees who entered the space of a fabricated tank for inspection and/or fabrication purposes.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B01 I
- Issued
- Jul 23, 2014
- Abate by
- Aug 1, 2014
- Penalty
- Initial $2,310 · Current $1,155 Reduced
General-duty citation text
29 CFR 1910.303(b)(1)(i): Electric equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees. Safety of equipment was determined under suitability for installation and use in conformity with this subpart: a. Perry Fiberglass Products, Inc. - Avon Lake, Ohio: On or about February 6, 2014, an extension cord, used to power the cut-off saw in Plant 2, was not free from electrical hazards in that materials stored on top of the cord created pinch points and exposed employees to electrical shock hazards.
Recent events (2)
- — I (S) $1155
- — Z (S) $2310
1910.304 G05
- Issued
- Jul 23, 2014
- Abate by
- Aug 1, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a. Perry Fiberglass Products, Inc. - Avon Lake, Ohio: On or about February 13, 2014, employees were exposed to electrical shock hazards in that a portable cut off saw was powered by an extension cord with a missing ground pin. The saw was used in Plant 2 to cut wood blocks.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.151 C
- Issued
- Jul 23, 2014
- Abate by
- Aug 8, 2014
- Penalty
- Initial $7,700 · Current $3,850 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes or body were not provided within the work area for immediate emergency use: a. Perry Fiberglass Products, Inc. - Avon Lake, Ohio: On or about February 13, 2013, the employer did not ensure the self-contained eyewash located on the West wall of Plant 1 was filled with eyewash solution. The eyewash station was empty. b. Perry Fiberglass Products, Inc. - Avon Lake, Ohio: On or about February 13, 2014, the employer did not ensure the self-contained eyewash located on the South end of Plant 1, near the offices, was filled with eyewash solution. The eyewash station was empty. c. Perry Fiberglass Products, Inc. - Avon Lake, Ohio: On or about February 13, 2014, the employer did not ensure the self-contained eyewash located on the North end of Plant 2, near the break room area, was filled with eyewash solution. The eyewash station was less than half full of eye wash solution. d. Perry Fiberglass Products, Inc. - Avon Lake, Ohio: On or about February 13, 2014, the employer did not ensure the self-contained eyewash located on the South End of Plant 2 was filled with eyewash solution. The eyewash station was approximately one-third full of eyewash solution. Perry Fiberglass Products, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.151(c), which was contained in OSHA inspection number 313781320, citation number 1, item number 4 and was affirmed as a final order on June 30, 2010, with respect to a workplace located at 33660 Pin Oak Pkwy., Avon Lake, Ohio 44012.
Recent events (2)
- — I (R) $3850
- — Z (R) $7700
1910.1200 F06 I
- Issued
- Jul 23, 2014
- Penalty
- Initial $7,700 · Current $3,850 Reduced
004017502280
General-duty citation text
29 CFR 1910.1200(f)(6)(i): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information required by 29 CFR 1910.1200(f)(1)(i) through 29 CFR 1910.1200(f)(1)(v): a. Perry Fiberglass Products, Inc. - Avon Lake, Ohio: On or about February 13, 2014, the employer did not ensure containers of acetone located in the Winder 1 area were labeled as to the identity of the substance. b. Perry Fiberglass Products, Inc. - Avon Lake, Ohio: On or about February 13, 2014, the employer did not ensure a container of styrene resin and Norox methyl ethyl ketone peroxide mixture located in the Winder 1 area was labeled as to the identity of the substance. Perry Fiberglass Products, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.1200(f)(5)(i), which was contained in OSHA inspection number 313781320, citation number 1, item number 6(a) and was affirmed as a final order on June 30, 2010, with respect to a workplace located at 33660 Pin Oak Pkwy., Avon Lake, Ohio 44012.
Recent events (2)
- — I (R) $3850
- — Z (R) $7700
1910.1200 F06 II
- Issued
- Jul 23, 2014
- Penalty
- Initial $0 · Current $0
004017502280
General-duty citation text
29 CFR 1910.1200(f)(6)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with product identifier and words, pictures, symbols, or combination thereof, which provided at least general information regarding the hazards of the chemicals: a. Perry Fiberglass Products, Inc. - Avon Lake, Ohio: On or about February 13, 2014, the employer did not ensure containers of acetone located in the Winder 1 area were labeled as to the physical and health hazards associated with the chemical. b. Perry Fiberglass Products, Inc. - Avon Lake, Ohio: On or about February 13, 2014, the employer did not ensure a container of styrene resin and methyl ethyl ketone peroxide mixture located in the Winder 1 area was labeled as to the physical and health hazards associated with the chemicals. Perry Fiberglass Products, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.1200(f)(5)(ii), which was contained in OSHA inspection number 313781320, citation number 1, item number 6(b) and was affirmed as a final order on June 30, 2010, with respect to a workplace located at 33660 Pin Oak Pkwy., Avon Lake, Ohio 44012.
Recent events (2)
- — I (R) $0
- — Z (R) $0
1910.134 H01 I
- Issued
- Jul 23, 2014
- Abate by
- Aug 8, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(h)(1)(i): Respirators issued for the exclusive use of an employee were not cleaned and disinfected as often as necessary to be maintained in a sanitary condition: a. Perry Fiberglass Products, Inc. - Avon Lake, Ohio: On or about February 13, 2014, the employer did not ensure that half face tight fitting respirators worn by employees fabricating/welding of fiberglass products in Plant 2 were maintained in a sanitary condition and cleaned to prevent contamination.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 H02 I
- Issued
- Jul 23, 2014
- Abate by
- Aug 8, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the facepiece and exhalation valve: a. Perry Fiberglass Products, Inc. - Avon Lake, Ohio: On or about February 13, 2014, the employer did not ensure that half face tight fitting respirators worn by employees fabricating/welding of fiberglass products in Plant 2 were stored to protect them from damage, and from dust created by grinding activities. A respirator was stored uncovered and hanging from shelving near the grinding operations.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Perry Fiberglass Products, INC.
View Perry Fiberglass Products, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339585036.