Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PERRY FIBERGLASS PRODUCTS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PERRY FIBERGLASS PRODUCTS, INC. in 611 LOWELL STREET, ELYRIA, OH 44035 (NAICS 326199). OSHA activity number 346466253.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Perry Fiberglass Products, INC. — free Get an email when a new federal OSHA severe-injury report for Perry Fiberglass Products, INC. is published. One employer, no account, unsubscribe in one click.
Site address
611 LOWELL STREET
City
ELYRIA
State
OH
ZIP
44035
Mailing
5415 VILLAGE DR., ROCKLEDGE, FL 32955
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
100
Ownership type
A

5 citations on file for this inspection.

1910.23 B10

Other-than-serious Gravity 10 1 instance 4 exposed
Issued
Apr 28, 2023
Abate by
May 16, 2023
Penalty
Initial $10,938 · Current $0 Reduced
29 CFR 1910.23(b)(10): The employer did not ensure that any ladder with structural or other defects as immediately tagged "Dangerous: Do Not Use" or with similar language and removed from service until repaired or replaced.  a) Perry Fiberglass Products Inc, on or about January 27, 2023, at the address of 611 Lowell Street Elyria, OH; Employees utilizing damaged ladders to access fiberglass tanks were exposed to fall hazards in that the employer failed to tag and remove damaged ladders from the production floor.
Recent events (2)
  • — I (O) $0
  • — Z (S) $10938

1910.179 G01 IV

Serious Gravity 5 1 instance 15 exposed
Issued
Apr 28, 2023
Abate by
May 16, 2023
Penalty
Initial $7,813 · Current $3,907 Reduced
29 CFR  1910.179(g)(1)(iv):Multiple conductor cable was used with a suspended pushbutton station, but the station was not supported in some satisfactory manner that protected the electrical conductors against strain:  a) Perry Fiberglass Products Inc, on or about January 27, 2023, at the address of 611 Lowell Street Elyria, OH; Employee's utilizing crane #2 to lift tanks were exposed to hazards associated with control reliability in that strain relief was not provided at the suspended pendent controller.
Recent events (2)
  • — I (S) $3907
  • — Z (S) $7813

1910.179 G01 V

Serious Gravity 5 1 instance 15 exposed
Issued
Apr 28, 2023
Abate by
May 16, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.179(g)(1)(v):Pendant control box(es) were not clearly marked for identification of functions:  a) Perry Fiberglass Products Inc, on or about January 27, 2023, at the address of 611 Lowell Street Elyria, OH; Employee's utilizing crane #2 to lift tanks were exposed to crushing injuries in that the employer failed to clearly mark functionality of pendent controller buttons.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.242 B

Serious Gravity 5 3 instances 74 exposed
Issued
Apr 28, 2023
Abate by
May 16, 2023
Penalty
Initial $9,376 · Current $4,687 Reduced
29 CFR  1910.242(b):Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  a) Perry Fiberglass Products Inc, on or about January 27, 2023, at the address of 611 Lowell Street Elyria, OH:  Employee's utilizing 118 PSI of compressed air to clean themselves off were exposed to eye injuries in that the employer failed to regulate airline to a pressure less than 30 PSI or provide chip guarding.
Recent events (2)
  • — I (S) $4687
  • — Z (S) $9376

1910.305 B02 I

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 28, 2023
Abate by
May 16, 2023
Penalty
Initial $7,813 · Current $3,907 Reduced
29 CFR  1910.305(b)(2)(i):Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  a) Perry Fiberglass Products Inc, on or about January 27, 2023, at the address of 611 Lowell Street Elyria, OH; The employer did not ensure 480v wiring was fully enclosed in junction box on block heater line. Employee operating in proximity of this condition were exposed to electrical hazards.
Recent events (2)
  • — I (S) $3907
  • — Z (S) $7813

View Perry Fiberglass Products, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346466253.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.