MOUNT PROSPECT, IL —
OSHA Inspection: SOLARIS ROOFING SOLUTIONS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SOLARIS ROOFING SOLUTIONS, INC. in 851 FEEHANVILLE, MOUNT PROSPECT, IL 60056 (NAICS 238160). OSHA activity number 339947152.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SOLARIS ROOFING SOLUTIONS, INC.
- Site address
- 851 FEEHANVILLE
- City
- MOUNT PROSPECT
- State
- IL
- ZIP
- 60056
- Mailing
- 31W023 NORTH AVENUE, WEST CHICAGO, IL 60185
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 9
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.501 B03
- Issued
- Sep 23, 2014
- Abate by
- Sep 29, 2014
- Penalty
- Initial $3,850 · Current $3,850
General-duty citation text
29 CFR 1926.501(b)(3): Each employee in a hoist area was not protected from falling 6 feet (1.8m) or more to lower levels by guardrail systems or personal fall arrest systems: a) Employees were exposed to the hazard of falling approximately 20 feet while working in a hoist area at the edge of the roof deck. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $3850
- — Z (S) $3850
1926.502 F01 III
- Issued
- Sep 23, 2014
- Penalty
- Initial $3,850 · Current $0 Reduced
General-duty citation text
29 CFR 1926.502(f)(1)(iii): Points of access, material handling areas, storage areas, and/or hoisting areas were not connected to the work area by an access path formed by two warning lines: a) Warning lines were not used to create access paths connecting the work area to the point of access along the roof edge. No abatement certification or documentation required for this violation.
Recent events (2)
- — I (S) $0
- — Z (S) $3850
1926.502 F02 II
- Issued
- Sep 23, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(f)(2)(ii): Warning line systems were not rigged and supported in such a way that its lowest point (including sag) was not less than 34 inches from the walking/working surface: a) A warning line system positioned along the edge of the roof deck at the point of access was not rigged and supported to prevent sagging below 34 inches. No abatement certification or documentation required for this violation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.502 F04
- Issued
- Sep 23, 2014
- Abate by
- Sep 29, 2014
- Penalty
- Initial $5,390 · Current $4,150 Reduced
General-duty citation text
29 CFR 1926.502(f)(4): Mechanical equipment on roofs was used or stored in areas where employees were not protected by a warning line system, guardrail system, or personal fall arrest system: a) Employees were exposed to the hazard of falling approximately 20 feet while operating mechanical equipment at and along the roof edge without the benefit of fall protection. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $4150
- — Z (S) $5390
1926.1053 B04
- Issued
- Sep 23, 2014
- Penalty
- Initial $3,080 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) Employees were exposed to the hazard of falling approximately 5 feet while climbing on a stepladder without its metal spreaders or locking devices in the open position. b) Employees were exposed to the hazard of falling approximately 5 feet while using a stepladder for access and egress between a lower roof deck and an upper roof deck. No abatement certification or documentation required for this violation.
Recent events (2)
- — I (O) $0
- — Z (S) $3080
More inspections at Solaris Roofing Solutions, INC.
View Solaris Roofing Solutions, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in IL