OSHA Inspection: SOLARIS ROOFING SOLUTIONS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SOLARIS ROOFING SOLUTIONS, INC. in 4915 N BIG HOLLOW ROAD, PEORIA, IL 61615 (NAICS 238160). OSHA activity number 348345471.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Solaris Roofing Solutions, INC. — free Get an email when a new federal OSHA severe-injury report for Solaris Roofing Solutions, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4915 N BIG HOLLOW ROAD
City
PEORIA
State
IL
ZIP
61615
Mailing
1 N 050 LINLAR DRIVE, ELBURN, IL 60119
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
27
Ownership type
A

4 citations on file for this inspection.

1926.20 B02

Serious Gravity 5 1 instance 6 exposed
Issued
Aug 15, 2025
Abate by
Sep 2, 2025
Penalty
Initial $9,931 · Current $6,950 Reduced
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials, and equipment to be made by a competent person:  On or about June 30, 2025, employees were exposed to a fall hazard of approximately 25 feet while performing construction activities including installing roofing material because the employer did not ensure a competent person conducted frequent and regular inspections of the worksite and equipment to identify the workplace hazards.
Recent events (2)
  • — I (S) $6950
  • — Z (S) $9931

1926.502 H01

Deleted Serious Gravity 5 1 instance 6 exposed
Issued
Aug 15, 2025
Abate by
Sep 2, 2025
Penalty
Initial $0 · Current $0
29 CFR 1926.502(h)(1): The employer did not designate a competent person to monitor the safety of other employees and/or did not ensure that the safety monitor complied with the requirements listed in (h)(1)(i) through (h)(1)(v) of this section:  On or about June 30, 2025, employees were exposed to a fall hazard of approximately 25 feet while performing construction activities including installing roofing material because the employer did not ensure a safety monitor was designated for the job.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B10

Serious Gravity 10 1 instance 5 exposed
Issued
Aug 15, 2025
Abate by
Sep 2, 2025
Penalty
Initial $13,902 · Current $9,730 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, warning line system and personal fall arrest system, or warning line system and safety monitoring system; or, on roofs 50 feet (15.25 m) or less in width, the use of a safety monitoring system alone:  On or about June 30, 2025, employees were exposed to a fall hazard of approximately 25 feet while installing roofing material because suitable fall protection system was not used.  THE SOLARIS ROOFING SOLUTIONS, INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 29 CFR 1926.501(b)(10), WHICH WAS CONTAINED IN OSHA INSPECTION 1557696, CITATION NUMBER 1, ITEM NUMBER 1a AND WAS AFFIRMED AS A FINAL ORDER ON JANUARY 19, 2022, WITH RESPECT TO A WORKPLACE LOCATED AT 3526 OAKTON STREET, SKOKIE, ILLINOIS 60076.
Recent events (2)
  • — I (S) $9730
  • — Z (R) $13902

1926.503 B01

Deleted Other-than-serious 1 instance 6 exposed
Issued
Aug 15, 2025
Abate by
Sep 2, 2025
Penalty
Initial $0 · Current $0
29 CFR 1926.503(b)(1): The employer did verify compliance with paragraph (a) of this section by preparing a written certification record. The written certification record shall contain the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. If the employer relies on training conducted by another employer or completed prior to the effective date of this section, the certification record shall indicate the date the employer determined the prior training was adequate rather than the date of actual training:  On or about June 30, 2025, employees were exposed to a fall hazard of approximately 25 feet while performing construction activities including installing roofing material and the employer did not have a written certification record containing the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the employer.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Solaris Roofing Solutions, INC.'s full OSHA safety record →