Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: U.S. DEPT. OF INTERIOR - NATIONAL PARK SERVICE - SEQUOIA & KINGS CANYON

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S. DEPT. OF INTERIOR - NATIONAL PARK SERVICE - SEQUOIA & KINGS CANYON in ASH MOUNTAIN MAINT. FACILITIES 47050 GENERALS HIGHWAY, THREE RIVERS, CA 93271 (NAICS 712190). OSHA activity number 341652931.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Dept. of Interior - National Park Service - Sequoia & Kings Canyon for free Get an email when a new federal OSHA severe-injury report for U.S. Dept. of Interior - National Park Service - Sequoia & Kings Canyon is published. One employer, no account, unsubscribe in one click.
Site address
ASH MOUNTAIN MAINT. FACILITIES 47050 GENERALS HIGHWAY
City
THREE RIVERS
State
CA
ZIP
93271
Mailing
47050 GENERALS HIGHWAY, THREE RIVERS, CA 93271
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
712190
Employees
570
Ownership type
Federal government (D)

5 citations on file for this inspection.

1910.212 A01

Repeat Gravity 5 1 instance 2 exposed
Issued
Sep 16, 2016
Abate by
Nov 30, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:     Ash Mountain Maintenance Facility Recycling Area, Sequoia National Park, 07/13/2016: The Vickers baler interlock system was not functional. The baler was operated with the door open while employees placing card board boxes in it, which exposed them to amputation and crushing hazards.     The U.S. National Park Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.212(a)(1), which was contained in OSHA inspection number 913225, citation number 01, item number 03 and was affirmed as a final order on 11/12/2013, with respect to a workplace located at Grant Grove, 83715 Park Road, Kings Canyon National Park, CA 93633.    The U.S. National Park Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.212(a)(1), which was contained in OSHA inspection number 913218, citation number 01, item number 03 and was affirmed as a final order on 11/12/2013, with respect to a workplace located at Cedar Grove, 1604 Death Valley Lane, Kings Canyon National Park, CA 93633.    The U.S. National Park Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.212(a)(1), which was contained in OSHA inspection number 913233, citation number 01, item number 06 and was affirmed as a final order on 11/12/2013, with respect to a workplace located at Clover Creek Waste Water Treatment Plant, 164100 Generals Highway, Sequoia National Park, CA 93262.    The U.S. National Park Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.212(a)(1), which was contained in OSHA inspection number 913208, citation number 01, item number 04 and was affirmed as a final order on 11/12/2013, with respect to a workplace located at Ash Mountain, 47050 Generals Highway, Sequoia National Park, CA 93262.
Recent events (2)
  • · I (R) $0
  • · Z (R) $0

1910.37 B02

Repeat 1 instance 1 exposed
Issued
Sep 16, 2016
Abate by
Nov 30, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":    Ash Mountain Maintenance Facility Radio Shop, Sequoia National Park, 07/13/2016: A designated exit door near the Supervisor's Office was not marked with a sign reading "Exit".    The U.S. National Park Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.37(b)(2), which was contained in OSHA inspection number 913225, citation number 01, item number 001 and was affirmed as a final order on 11/12/2013, with respect to a workplace located at  Grant Grove, 83715 Park road, Kings Canyon National Park, CA. 93633.
Recent events (2)
  • · I (R) $0
  • · Z (R) $0

1910.212 B

Repeat 1 instance 2 exposed
Issued
Sep 16, 2016
Abate by
Nov 30, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:    Ash Mountain Maintenance Facility Radio Shop, Sequoia National Park, 07/13/2016: The Black and Decker 6 inch pedestal grinder was not anchored to the floor.    The U.S. National Park Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard29 CFR 1910.212(b), which was contained in OSHA inspection number 913233, citation number 01, item number 001 and was affirmed as a final order on 11/12/2013, with respect to a workplace located at Clover Creek Waste Water Treatment Plant 64100 Generals Highway, Sequoia National Park, CA 93262.
Recent events (2)
  • · I (R) $0
  • · Z (R) $0

1910.157 C01

Other-than-serious 2 instances 2 exposed
Issued
Sep 16, 2016
Abate by
Nov 30, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries.    Ash Mountain Maintenance Facility, Sequoia National Park, 07/13/2016: Two fire extinguishers were not mounted on the hooks provided. The fire extinguishers were placed on the floor in the following locations;        a. Electrical Shop          b. Automotive Shop
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.242 B

Other-than-serious 3 instances 3 exposed
Issued
Sep 16, 2016
Abate by
Nov 30, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i. :    Ash Mountain Maintenance Facility, Sequoia National Park, 07/13/2016: The compressed air used for cleaning was reduced to 30 p.s.i. in the following locations;        a. Roadway Shop - compressed air measured at 70 p.s.i.        b. Sign Shop - compressed air measured at 80 p.s.i.        c. Auto Maintenance Shop - compressed air measured at 85 p.s.i.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View U.S. Dept. of Interior - National Park Service - Sequoia & Kings Canyon's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341652931.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.