NEENAH, WI —
OSHA Inspection: NEENAH ENTERPRISES INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of NEENAH ENTERPRISES INC. in 2121 BROOKS AVE, NEENAH, WI 54956 (NAICS 331511). OSHA activity number 345839120.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NEENAH ENTERPRISES INC.
- Site address
- 2121 BROOKS AVE
- City
- NEENAH
- State
- WI
- ZIP
- 54956
- Mailing
- 2121 BROOKS AVE, NEENAH, WI 54956
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331511
- Employees
- 700
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.1000 A02
- Issued
- Aug 12, 2022
- Abate by
- Sep 12, 2022
- Penalty
- Initial $12,431 · Current $6,216 Reduced
0560
General-duty citation text
29 CFR 1910.1000(a)(2): An employee's exposure to any substance in Table Z-1, the exposure limit of which is not preceded by a "C", shall not exceed the 8-hour Time Weighted Average given for that substance any 8-hour work shift of a 40-hour work week: At a workplace located at 2121 Brooks Avenue, Neenah, WI 54956: On March 9, 2022, a KW Deck Lead employee operating the Plant 2 KW Junker auto-pour from the pour deck was exposed to an 8-hour time weighted average (TWA) of 62.0 ppm for carbon monoxide (CO), approximately 1.2 times the Permissible Exposure Limit (PEL) of 50 ppm. The exposure level was derived from a carboxyhemoglobin blood sample collected after a 340 minute exposure period with zero exposure assumed for the unsampled period of 140 minutes.
Recent events (2)
- — I (S) $6215.5
- — Z (S) $12431
1910.1000 E
- Issued
- Aug 12, 2022
- Abate by
- Sep 12, 2022
- Penalty
- Initial $0 · Current $0
0560
General-duty citation text
29 CFR 1910.1000(e): To achieve compliance with paragraphs (a) through (d) of this section, administrative or engineering controls must first be determined and implemented whenever feasible. When such controls are not feasible to achieve full compliance, protective equipment or any other protective measures shall be used to keep the exposure of employees to air contaminants within the limits prescribed in this section. Any equipment and/or technical measures used for this purpose must be approved for each particular use by a competent industrial hygienist or other technically qualified person. Whenever respirators are used, their use shall comply with 1910.134: At a workplace located at 2121 Brooks Avenue, Neenah, WI 54956; the employer did not implement administrative and engineering controls to achieve compliance with paragraph (a) of this section when a KW Deck Lead employee operating the Plant 2 KW Junker auto-pour from the pour deck was exposed to carbon monoxide exceeding the 8-hour time weighted average (TWA) Permissible Exposure Limit (PEL) of 50 ppm.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H03 I
- Issued
- Aug 12, 2022
- Abate by
- Oct 3, 2022
- Penalty
- Initial $12,431 · Current $6,216 Reduced
0560C730
General-duty citation text
29 CFR 1910.1200(h)(3)(i): Employee training shall include methods and observations that may be used to detect the presence or release of a hazardous chemical in the work area (such as monitoring conducted by the employer, continuous monitoring devices, visual appearance or odor of hazardous chemicals when being released, etc.): At a facility located at 2121 Brooks Avenue, Neenah, WI 54956; employee training did not include methods and observations that may be used to detect the presence or release of a hazardous chemical in the work area. Employees exposed to carbon monoxide, as a byproduct of combustion in the iron melting/pouring process, in the workplace were not trained how to detect the presence or release of the odorless and colorless hazardous chemical.
Recent events (2)
- — I (S) $6215.5
- — Z (S) $12431
1910.1200 H03 II
- Issued
- Aug 12, 2022
- Abate by
- Oct 3, 2022
- Penalty
- Initial $0 · Current $0
0560C730
General-duty citation text
29 CFR 1910.1200(h)(3)(ii): Employee training shall include the physical, health, simple asphyxiation, combustible dust, and pyrophoric gas hazards, as well as hazards not otherwise classified, of the chemicals in the work area: At a facility located at 2121 Brooks Avenue, Neenah, WI 54956; employee training did not include health hazards of chemicals in the work area. Employees exposed to carbon monoxide, as a byproduct of combustion in the iron melting/pouring process in the workplace, were not trained on the health hazards of carbon monoxide such as but not limited to chemical asphyxia, headache, tachypnea, nausea, lassitude (weakness, exhaustion), dizziness, confusion, angina, or syncope.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H03 III
- Issued
- Aug 12, 2022
- Abate by
- Oct 3, 2022
- Penalty
- Initial $0 · Current $0
0560C730
General-duty citation text
29 CFR 1910.1200(h)(3)(iii): Employee training shall include the measures employees can take to protect themselves from these hazards, including specific procedures the employer has implemented to protect employees from exposure to hazardous chemicals, such as appropriate work practices, emergency procedures, and personal protective equipment to be used: At a facility located at 2121 Brooks Avenue, Neenah, WI 54956; employee training did not include measures employees could take to protect themselves from the health hazards of chemicals in the work area. Employees were not trained on specific procedures, such as appropriate work practices or emergency procedure to protect employees from exposure to carbon monoxide, as a byproduct of combustion in the iron melting/pouring process, in the workplace.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Neenah Enterprises INC.
View Neenah Enterprises INC.'s full OSHA safety record →
More inspections in this industry (NAICS 331511)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345839120.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.