OKARCHE, OK —
OSHA Inspection: DCP MIDSTREAM LP
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DCP MIDSTREAM LP in 30398 N2760 RD, OKARCHE, OK 73762 (NAICS 325110). OSHA activity number 339988537.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DCP MIDSTREAM LP
- Site address
- 30398 N2760 RD
- City
- OKARCHE
- State
- OK
- ZIP
- 73762
- Mailing
- 30398 N2760 RD, OKARCHE, OK 73762
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325110
- Employees
- 11
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.119 J04 II
- Issued
- Jan 8, 2015
- Abate by
- Jan 26, 2015
- Penalty
- Initial $7,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.119(j)(4)(ii): Inspections and testing procedures performed on process equipment to maintain its mechanical integrity, does not follow recognized and generally accepted good engineering practices. The employer does not ensure inspections and tests performed to maintain the on-going mechanical integrity of process equipment followed recognized and generally accepted good engineering practices (RAGAGEP). The violation occurred in the Okarche Gas Plant on or about October 7, 2014 and at times prior thereto. Employees were exposed to fire and explosion hazards when the employer failed to ensure inspections and tests were performed on process equipment pressure relief valves/devices in accordance with RAGAGEP such as API 510 & 576. Identified relief valves/devices include but are not limited to: a. PSV-15 NGL Surge Tank b. PSV-55 Inlet Receiver c. PSV-4 Condensate Flash Tank d. PSV-23 Reflux Accumulator e. PSV-71 Amine Surge Tank f. PSV-12 Fuel Gas Scrubber Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date the employer must submit documentation showing it is in compliance with the standard, including describing the steps it is taking to ensure inspections and tests are performed to maintain the on-going mechanical integrity of process equipment followed recognized and generally accepted good engineering practices (RAGAGEP).
Recent events (3)
- — F (S) $0
- — C (S) $7000
- — Z (S) $7000
1910.119 E03 V
- Issued
- Jan 8, 2015
- Abate by
- Sep 27, 2016
- Penalty
- Initial $35,000 · Current $20,000 Reduced
General-duty citation text
29 CFR 1910.119(e)(3)(v): The process hazard analysis did not adequately address facility siting. The employer does not ensure the process hazard analysis addressed facility siting adequately. a. The violation occurred on or about October 7, 2014 and times prior thereto in the Okarche Gas Plant where the employer exposed employees to fire and explosion hazards when it failed to ensure the process hazard analysis adequately addressed the siting of the control room and other personnel occupied buildings in the facility. DCP Midstream LP was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.119 (e)(3)(v) which was contained in OSHA inspection number 910522, citation number 01 item number 01 and was affirmed as a final order on November 25, 2013 with respect to a workplace located at 594 South State Highway 163, Ozona, Texas 76943. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date the employer must submit documentation showing it is in compliance with the standard, including describing the steps it is taking to ensure the process hazard analysis addressed facility siting adequately.
Recent events (3)
- — F (R) $20000
- — C (R) $35000
- — Z (R) $35000
More inspections at DCP Midstream LP
View DCP Midstream LP's full OSHA safety record →
More inspections in this industry (NAICS 325110)
More inspections in OK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339988537.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.